MétaCan
Menu
Back to cohort
Record W2794231190 · doi:10.1117/12.2293664

Breast elastography: Identification of benign and malignant cancer based on absolute elastic modulus measurement using vibro-elastography

2018· article· en· W2794231190 on OpenAlexaff
Ana Cecilia Saavedra, Jorge Guerrero, Pilar Montenegro, Jorge Aguilar, Joseph A. Pinto, Julio Lobo, Tim Salcudean, Roberto Lavarello, Benjamín Castañeda, Junior Arroyo

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsElastographyMedicineBreast cancerRadiologyUltrasoundBiopsyCutoffElasticity (physics)CancerInternal medicineMaterials science

Abstract

fetched live from OpenAlex

Breast cancer is a public health problem with ~ 1.7 million new cases per year worldwide and with several limitations in the state-of-art screening techniques. Ultrasound elastography involves a set of techniques intended to facilitate the noninvasive diagnosis of cancer. Among these, Vibro-elastography is an ultrasound-based technique that employs external mechanical excitation to infer the elastic properties of soft tissue. In this paper, we evaluate the Vibro-elastography performance in the differentiation of benign and malignant breast lesions. For this study, a group of 18 women with clinically confirmed tumors or suspected malignant breast lesions were invited to participate. For each volunteer, an elastogram was obtained, and the mean elasticity of the lesion and the adjacent healthy tissue were calculated. After the acquisition, the volunteers underwent core-needle biopsy. The histopathological results allowed to validate the Vibro-elastography diagnosis, which ranged from benign to malignant lesions. Results indicate that the mean elasticity value of the benign lesions, malignant lesions and healthy breast tissue were 39.4 ± 12 KPa, 55.4 ± 7.02 KPa and 23.91 ± 4.57 kPa, respectively. The classification between benign and malignant breast cancer was performed using Support Vector Machine based on the measured lesion stiffness. A ROC curve permitted to quantify the accuracy of the differentiation and to define a suitable cutoff value of stiffness, obtaining an AUC of 0.90 and a cutoff value of 44.75 KPa. The results obtained suggest that Vibro-elastography allows differentiating between benign and malignant lesions. Furthermore, the elasticity values obtained for benign, malignant and healthy tissue are consistent with previous reports.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.266
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes1
Has abstractyes

Explore more

Same topicUltrasound Imaging and ElastographyFrench-language works237,207