MétaCan
Menu
Back to cohort
Record W2794971517 · doi:10.1007/s12350-018-1261-4

Saline-push improves rubidium-82 PET image quality

2018· article· en· W2794971517 on OpenAlexaff
Jennifer M. Renaud, Kai Yi Wu, Kimberly Gardner, May Aung, Rob Beanlands, Robert A. deKemp

Bibliographic record

VenueJournal of Nuclear Cardiology · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineSalineVentricleMyocardial perfusion imagingImage qualityNuclear medicinePerfusionCardiac PETPet imagingCoefficient of variationRadiologyPositron emission tomographyInternal medicine

Abstract

fetched live from OpenAlex

Rubidium-82 (82Rb) PET is used widely for myocardial perfusion imaging. The purpose of this study was to investigate if an additional saline-push following the 82Rb elution improves PET image quality. 82Rb PET scans were acquired with and without 26 mL saline-push in six patients as part of a clinical quality improvement program. Dynamic images were analyzed to measure the total activity delivered to the superior vena cava (SVC) and retained in the left ventricle (LV) myocardium. Tracer uptake images were used to measure blood background coefficient-of-variation (COV), myocardium-to-blood signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) to assess image quality. Similar eluted activity was measured with/without the saline-push (830 vs 795 MBq; P = 0.24). The activity delivered to the heart and retained in the myocardium was consistently increased more than twofold (SVC: + 114% and LV: + 104%; P < 0.001) with the saline-push. Image quality was improved in all patients, with lower background noise (COV: − 19%), higher SNR (+ 24%) and CNR (+ 27%) (all P ≤ 0.01). The saline-push used to flush 82Rb activity out of the infuser tubing, patient injection and intravenous access lines consistently increased the activity delivered to the heart by twofold. This technique is recommended to maximize image quality with 82Rb PET.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.577
Threshold uncertainty score0.291

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.367
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear CardiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207