MétaCan
Menu
Back to cohort
Record W2795530227 · doi:10.1109/tia.2018.2823680

Harmonics and Mitigation Techniques Through Advanced Control in Grid-Connected Renewable Energy Sources: A Review

2018· review· en· W2795530227 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueIEEE Transactions on Industry Applications · 2018
Typereview
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsHarmonicsHarmonicInverterElectrical engineeringTotal harmonic distortionInterfacingElectronic engineeringPhotovoltaic systemDistributed generationRenewable energyMaximum power point trackingEngineeringElectric power systemComputer sciencePower (physics)VoltagePhysicsAcoustics

Abstract

fetched live from OpenAlex

With more renewable energy based distributed generation (DG) units connected to utility power grids, deterioration of power quality at the point of common coupling (PCC) becomes a major concern. There are two types of harmonics associated with DG units, and together they may cause excessive harmonic distortion at the PCC. The first type of harmonics is generated by power electronic devices in DG units such as photovoltaic systems, which contains high-frequency harmonic components at multiples of the carrier frequency of the DG interfacing inverter. Such harmonics are first reviewed in this paper, and the potential operational effect at the system level due to LCL or LC filters installed at the inverter output to mitigate such harmonics are discussed. The second type of harmonics is generated by other nonlinear local, PCC, and utility loads in the system, which are common type of harmonics at multiples of the power grid frequency, 50/60 Hz. Harmonic mitigation for such harmonics achieved through advanced control of the DG interfacing inverter operated as a power quality conditioner are reviewed and summarized. This systematic review can facilitate better understanding of harmonics associated with renewable energy based DG units and provide guidelines on advanced control schemes to realize ancillary harmonic compensation service through DG interfacing inverters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.981
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.260
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it