MétaCan
Menu
Back to cohort
Record W2795530227 · doi:10.1109/tia.2018.2823680

Harmonics and Mitigation Techniques Through Advanced Control in Grid-Connected Renewable Energy Sources: A Review

2018· review· en· W2795530227 on OpenAlexaff
Xiaodong Liang, Chowdhury Andalib-Bin-Karim

Bibliographic record

VenueIEEE Transactions on Industry Applications · 2018
Typereview
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsHarmonicsHarmonicInverterElectrical engineeringTotal harmonic distortionInterfacingElectronic engineeringPhotovoltaic systemDistributed generationRenewable energyMaximum power point trackingEngineeringElectric power systemComputer sciencePower (physics)VoltagePhysicsAcoustics

Abstract

fetched live from OpenAlex

With more renewable energy based distributed generation (DG) units connected to utility power grids, deterioration of power quality at the point of common coupling (PCC) becomes a major concern. There are two types of harmonics associated with DG units, and together they may cause excessive harmonic distortion at the PCC. The first type of harmonics is generated by power electronic devices in DG units such as photovoltaic systems, which contains high-frequency harmonic components at multiples of the carrier frequency of the DG interfacing inverter. Such harmonics are first reviewed in this paper, and the potential operational effect at the system level due to LCL or LC filters installed at the inverter output to mitigate such harmonics are discussed. The second type of harmonics is generated by other nonlinear local, PCC, and utility loads in the system, which are common type of harmonics at multiples of the power grid frequency, 50/60 Hz. Harmonic mitigation for such harmonics achieved through advanced control of the DG interfacing inverter operated as a power quality conditioner are reviewed and summarized. This systematic review can facilitate better understanding of harmonics associated with renewable energy based DG units and provide guidelines on advanced control schemes to realize ancillary harmonic compensation service through DG interfacing inverters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.260
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations257
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Industry ApplicationsSame topicMicrogrid Control and OptimizationFrench-language works237,207