MétaCan
Menu
Back to cohort
Record W2796781527 · doi:10.1177/0267659118766434

Use of a tracheal dilator for percutaneous insertion of 27F and 31F Avalon <sup>©</sup> dual-lumen cannulae for veno-venous extracorporeal membrane oxygenation in adults

2018· article· en· W2796781527 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenuePerfusion · 2018
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsHôpital du Sacré-Cœur de Montréal
Fundersnot available
KeywordsMedicineCannulaDilatorPercutaneousLumen (anatomy)Extracorporeal membrane oxygenationSurgeryAnesthesia

Abstract

fetched live from OpenAlex

Veno-venous extracorporeal membrane oxygenation can be performed either by two cannulae or by a single dual-lumen cannula. The dual-lumen cannulation configuration offers multiple advantages: it avoids the femoral site which may be at greater risk of infection, it improves patient mobility, eases prone positioning and greatly reduces recirculation. The Avalon was the first commercially available dual-lumen cannula for adults. It has gained much popularity, but, for more than a year now, the adult vascular access kit with the 30Fr dilator has been discontinued in the United Kingdom. In this article, we share our experience with an alternative insertion method, using a percutaneous dilatational tracheostomy kit. This off-label use of the tracheostomy dilator appears to be safe. It may allow the continuing use of Avalon dual-lumen cannulae while waiting for a more permanent solution to be provided by the manufacturer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.920
Threshold uncertainty score0.745

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.230
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it