MétaCan
Menu
← Back to cohort
Record W2802556209 · doi:10.1111/cid.12611

Evaluation of the effect of self‐cutting and nonself‐cutting thread designed implant with different thread depth on variable insertion torques: An histomorphometric analysis in rabbits

2018· article· en· W2802556209 on OpenAlexvenueno aff
Anand Kumar Muktadar, Makam Gangaiah, Bruno Ramos Chrcanovic, Ramesh Chowdhary

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2018
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsThread (computing)TorqueScrew threadImplantMaterials scienceBiomedical engineeringDentistrySurgeryMedicineEngineeringMechanical engineeringPhysics

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate of the effect of self-cutting and nonself-cutting thread designed implant with different thread depth on variable insertion torques. To evaluate the bone volume (BV) and bone to implant contact (BIC) in these variables MATERIALS AND METHODS: Mainly two thread design, V-shaped thread which is self-cutting and power thread design, which is nonself-cutting implants were considered for this study with a variation in thread depth of 0.4 and 0.6 mm for both the designs, respectively. A total of 32 CAD designed machined surface implant prototypes were manufactured of 4 mm in diameter and 8 mm in length were made, which were machined surfaced, which was placed in the femur of 16 New Zealand white rabbits. These were categorized under 2 groups; Group 1 and Group 2 with insertion torques of <30 and >50 Ncm, respectively. After 4 weeks of healing, rabbits were sacrificed and histomophometric and histologic analyses were done to evaluate the bone response. RESULTS: Significantly, more BIC was recorded for high torque implants compared with low torque in power-shaped thread design (P value = .01*). BV for new bone formation was statistically significant for V-shaped thread design in high torque when compared with low torque (P value = .02*). CONCLUSION: The effect of the depth of the thread design was significant for the power-shaped design in enhancing BIC when compared with V-shaped thread design. With high torque V-shaped thread design had more new bone formation as compared with power-shaped thread design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.108
GPT teacher head0.446
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→