MétaCan
Menu
Back to cohort
Record W2803199303 · doi:10.1115/es2013-18207

In-Situ Experimental Validation of THERM Finite Element Analysis for a High R-Value Wall Using Vacuum Insulation Panels

2013· article· en· W2803199303 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicSolar Energy Systems and Technologies
Canadian institutionsCarleton University
Fundersnot available
KeywordsVacuum insulated panelThermal resistanceThermal insulationHeat fluxMechanical engineeringFinite element methodEngineeringThermalStructural engineeringHeat transferMaterials scienceComposite materialMechanics

Abstract

fetched live from OpenAlex

Team Ontario is one of twenty collegiate teams selected to design and build a solar powered, net positive home for the U.S. Department of Energy Solar Decathlon 2013. One aspect of Team Ontario’s competition design entry is a high R-value wall using vacuum insulation panels. This paper details the method used for theoretical evaluation of the high R-value wall, stating all simplifying assumptions made. Theoretical simulations were performed in THERM, a two dimensional finite element heat transfer modelling program. Following a weighted average method used by industry experts, the whole-wall thermal resistance value was calculated. To verify the modelling results, an in-situ experimental validation was conducted. An 8′ × 8′ wall test specimen was built to the specifications of Team Ontario’s wall design. Experimental heat flux and temperature readings were collected from the test specimen in Carleton University’s Vacuum Insulation Test Facility located in Ottawa, Ontario, Canada, with the test specimen exposed to exterior weather elements. The experimental and theoretical results are compared and conclusions drawn to determine the effective thermal resistance of the vacuum insulation panels installed in the wall assembly. Finally the theoretical model is refined based on the previous study and a more accurate whole-wall thermal resistance of Team Ontario’s wall design is determined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.153
Threshold uncertainty score0.305

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.248
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Quick stats

Citations2
Published2013
Admission routes2
Has abstractyes

Explore more

Same topicSolar Energy Systems and TechnologiesFrench-language works237,207