MétaCan
Menu
← Back to cohort
Record W2804049491 · doi:10.1117/12.2306130

Spectral retrieval techniques for high-resolution Fourier transform microspectrometers

2018· article· en· W2804049491 on OpenAlexafffund
Aitor V. Velasco, Alaine Herrero-Bermello, Hugh Podmore, Pavel Cheben, Jens H. Schmid, M. L. Calvo, Siegfried Janz, Dan‐Xia Xu, Alan Scott, Regina Lee

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicPhotonic and Optical Devices
Canadian institutionsHoneywell (Canada)National Research Council CanadaYork University
FundersEuropean Metrology Programme for Innovation and ResearchNational Research Council CanadaCanadian Space AgencyHorizon 2020 Framework ProgrammeMinisterio de Economía y CompetitividadNatural Sciences and Engineering Research Council of CanadaEuropean CommissionComunidad de MadridEuropean Association of National Metrology Institutes
KeywordsAstronomical interferometerInterferometrySpectrometerFourier transform spectroscopyFourier transformComputer scienceOpticsSilicon on insulatorSpectral resolutionImage resolutionMaterials scienceFourier transform infrared spectroscopyPhysicsOptoelectronicsSiliconSpectral line

Abstract

fetched live from OpenAlex

Spatial heterodyne Fourier transform (SHFT) spectroscopy is based on simultaneous interferometric measurements implementing linearly increasing optical path differences, hence circumventing the need for mechanical components of traditional Fourier transform spectroscopy schemes. By taking advantage of the high mode confinement of the Siliconon-Insulator (SOI). platform, great interferometric lengths can be implemented in a reduced footprint, hence increasing the resolution of the device. However, as resolution increases, spectrometers become progressively more sensitive to environmental conditions, and new spectral retrieval techniques are required. In this work, we present several software techniques that enhance the operation of high-resolution SHFT micro-spectrometers. Firstly, we present two techniques for mitigating and correcting the effects of temperature drifts, based on a temperature-sensitive calibration and phase errors correction. Both techniques are demonstrated experimentally on a 32 Mach-Zehnder interferometers array fabricated in a Silicon-on-insulator chip with microphotonic spirals of linearly increasing length up to 3.779 cm. This configuration provides a resolution of 17 pm in a compact device footprint of 12 mm2. Secondly, we propose the application of compressive-sensing (CS) techniques to SHFT micro-spectrometers. By assuming spectrum sparsity, an undersampled discrete Fourier interferogram is inverted using l1-norm minimization to retrieve the input spectrum. We demonstrate this principle on a subwavelength-engineered SHFT with 32 MZIs and a 50 pm resolution. Correct retrieval of three sparse input signals was experimentally demonstrated using data from 14 or fewer MZIs and applying common CS reconstruction techniques to this data.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.226
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2018
Admission routes2
Has abstractyes

Explore more

Same topicPhotonic and Optical Devices→French-language works237,207→