Abstract

fetched live from OpenAlex

PURPOSE: This article aims to report a new clinical finding associated with the wear of scleral lenses.
 METHODS: Non-contact lens wearer subjects were recruited and fitted with large diameter (18 mm) scleral lenses. Lens was randomly filled with non preserved saline or non preserved carboxymethylcellulose-based artificial tears (Refresh Celluvisc, Allergan, Ca). The sinking of the lens on the nasal and temporal sclera was assessed periodically during a total of 6h00 of wear, with the use of anterior segment coherence tomography (OCT- Optovue, Clarion Technologies, Texas). Images were taken every 30 minutes for the first 2h00, then at 4h00 and 6h00 post-insertion.
 RESULTS: The nasal side sinks significantly more than the temporal side by 23.0±7.3 μm (F(1,12)=10.043; p=0.008; 95%CI:[7.2 ,38.9]). This difference is significant with time (F=8.757; p<0.001) and there is a side effect (F=10.043; p=0.008). The type of solution does not influence the lens behavior (F=0.250; p=0.626). A new clinical finding was revealed during scan analysis. Conjunctival tissue displacement was seen, under the reverse curve of the scleral lens, shortly after insertion. This conjunctival “inlapse” (CI) was sustained over all the wearing hours. On the nasal quadrant, CI was reduced in height and present in only 8/15 subjects while, in the temporal quadrant, 100% of subjects showed an average CI of 38.39 ± 10.43 μm (t(84)=3.68; p=0.0072; 95%CI[17.64, 59.13]) 30 minutes post insertion followed by a non-significant decrease of 1.97 ± 10.34 μm (t(84)=0.19; p=1.00; 95%CI[-22.52,18.58]) between 30 minutes and 6 hours of wear.
 CONCLUSION: Nasal sinking is more pronounced as compared with temporal lens sinking. This may explain the occurrence of a new clinical phenomenon identified to happen shortly after lens insertion, under the reverse curve of a scleral lens. In fact, CI happens mostly on the temporal quadrant, where more space is available for the conjunctival tissue to move. This finding suggests that conjunctival tissue reacts to scleral lens wear, not only in the inferior quadrant, where conjunctival prolapse is known to occur, but in every other one as well.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.287
Threshold uncertainty score0.630

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0010.002
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.346
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Contact lens Research and ScienceSame topicOcular Surface and Contact LensFrench-language works237,207