MétaCan
Menu
Back to cohort
Record W2807112518 · doi:10.1109/tuffc.2018.2841848

The Role of Microbubble Echo Phase Lag in Multipulse Contrast-Enhanced Ultrasound Imaging

2018· article· en· W2807112518 on OpenAlexafffund
Charles Tremblay‐Darveau, Paul S. Sheeran, Cindy Kim Vu, Ross Williams, Ze Zhang, Matthew Bruce, Peter N. Burns

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2018
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of TorontoHealth Sciences CentreSunnybrook Health Science Centre
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of TorontoCanadian Institutes of Health ResearchLantheus Medical Imaging
KeywordsMicrobubblesAmplitudeAmplitude modulationMaterials scienceElasticity (physics)Second-harmonic imaging microscopyUltrasoundMechanical indexAcousticsNuclear magnetic resonanceOpticsFrequency modulationPhysicsRadio frequencySecond-harmonic generationComposite material

Abstract

fetched live from OpenAlex

In this paper, we assess the importance of microbubble shell composition for contrast-enhanced imaging sequences commonly used on clinical scanners. While the gas core dynamics are primarily responsible for the nonlinear harmonic response of microbubbles at diagnostic pressures, it is now understood that the shell rheology plays a dominant role in the nonlinear response of microbubbles subjected to low acoustic pressures. Of particular interest here, acoustic pressures of tens of kilopascal can cause a reversible phase transition of the phospholipid coatings from a stiff elastic organized state to a less stiff disorganized buckled state. Such a transition from elastic to buckled shell induces a steep variation of the shell elasticity, which alters the microbubble acoustic scattering properties. We demonstrate in this paper that this mechanism plays a dominant role in contrast pulse sequences that modulate the amplitude of the insonifying pulse pressure. The contrast-to-tissue ratio (CTR) for amplitude modulation (AM), pulse inversion (PI), and amplitude modulation pulse inversion (AMPI) is measured in vitro for Definity, Sonazoid, both lipid-encapsulted microbubbles, and the albumin-coated Optison. It is found that pulse sequences using AM significantly enhanced the nonlinear response of all studied microbubbles compared to PI (up to 15 dB more) when low insonation pressures under 200 kPa were used. Further investigation reveals that the origin of the hyperechoicity is a small phase lag occurring between the echoes from the full-and half-amplitude driving pulses, and that the effect could be attributed to the shell softening dynamics of lipid and albumin coatings. We assess that this additional phase in microbubble ultrasound scattering can have a dominant role in the CTR achieved in contrast sequences using AM. We also show that the pressure dependent phase lag is a specific marker for microbubbles with no equivalent in tissue, which can be used to segment microbubbles from the tissue harmonics and significantly increase the CTR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.633
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.210
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207