MétaCan
Menu
Back to cohort
Record W2807220353 · doi:10.2967/jnumed.118.209007

Feasibility of <sup>18</sup>F-FDG Dose Reductions in Breast Cancer PET/MRI

2018· article· en· W2807220353 on OpenAlexaff
Bert-Ram Sah, Soleen Ghafoor, Irene A. Burger, Edwin E. G. W. ter Voert, Tetsuro Sekine, Gaspar Delso, Martin W. Huellner, Konstantin J. Dedes, Andreas Boss, Patrick Veit‐Haibach

Bibliographic record

VenueJournal of Nuclear Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of TorontoUniversity Health Network
FundersUniversitätsspital Zürich
KeywordsWilcoxon signed-rank testNuclear medicineMedicineBreast cancerImage qualityImage noiseMann–Whitney U testIterative reconstructionLesionCancerMathematicsRadiologyPathologyArtificial intelligenceComputer scienceImage (mathematics)Internal medicine

Abstract

fetched live from OpenAlex

The goal of this study was to determine the level of clinically acceptable <sup>18</sup>F-FDG dose reduction in time-of-flight PET/MRI in patients with breast cancer. <b>Methods:</b> Twenty-six consecutive women with histologically proven breast cancer were analyzed (median age, 51 y; range, 34–83 y). Simulated dose-reduced PET images were generated by unlisting the list-mode data on PET/MRI. The acquired 20-min PET frame was reconstructed in 5 ways: a reconstruction of the first 2 min with 3 iterations and 28 subsets for reference, and reconstructions simulating 100%, 20%, 10%, and 5% of the original dose. General image quality and artifacts, image sharpness, image noise, and lesion detectability were analyzed using a 4-point scale. Qualitative parameters were compared using the nonparametric Friedman test for multiple samples and the Wilcoxon signed-rank test for paired samples. Different groups of independent samples were compared using the Mann–Whitney <i>U</i> test. <b>Results:</b> Overall, 355 lesions (71 lesions with 5 different reconstructions each) were evaluated. The 20-min reconstruction with 100% injected dose showed the best results in all categories. For general image quality and artifacts, image sharpness, and noise, the reconstructions with a simulated dose of 20% and 10% were significantly better than the 2-min reconstructions (<i>P</i> ≤ 0.001). Furthermore, 20%, 10%, and 5% reconstructions did not yield results different from those of the 2-min reconstruction for detectability of the primary lesion. For 10% of the injected dose, a calculated mean dose of 22.6 ± 5.5 MBq (range, 17.9–36.9 MBq) would have been applied, resulting in an estimated whole-body radiation burden of 0.5 ± 0.1 mSv (range, 0.4–0.7 mSv). <b>Conclusion:</b> Ten percent of the standard dose of <sup>18</sup>F-FDG (reduction of ≤90%) results in clinically acceptable PET image quality in time-of-flight PET/MRI. The calculated radiation exposure would be comparable to the effective dose of a single digital mammogram. A reduction of radiation burden to this level might justify partial-body examinations with PET/MRI for dedicated indications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.634
Threshold uncertainty score0.996

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.384
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207