MétaCan
Menu
Back to cohort
Record W2807958985 · doi:10.21767/2471-8505.100112

A Prospective Pilot Study of the Biometrics of Critical Care Practitioners during Live Patient Care using a Wearable "Smart Shirt"

2018· article· en· W2807958985 on OpenAlexaboutno aff
Nicholas Slamon, Scott Penfil, Vinay Nadkarni, Robert M. Parker

Bibliographic record

VenueJournal of Intensive and Critical Care · 2018
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineHeart rateHeart rate variabilityRespiratory rateIntensive care unitInternal medicinePhysical therapyCardiology

Abstract

fetched live from OpenAlex

Objective: To measure the biometrics (heart rate, heart rate variability) of critical care physicians during live clinical patient scenarios. Design: Participants wore the Hexoskin biometric smart shirt (Hexoskin, Carrè Technologies, Montreal, Quebec) during live clinical activities. Setting: 24-bed tertiary care children’s hospital pediatric intensive care unit. Subjects: Pediatric critical care attendings and fellows. Interventions: Heart rate (HR), respiratory rate (RR), and heart rate variability (HRV) were recorded during clinical shifts. Activities included subject baseline (SB), patient rounds (PR), tracheal intubation (TI), and central line insertion (CL). Measurements and main results: Mean HR for the activities SB, PR, TI, and CL were 81 ± 3.65, 85 ± 4.75, 99 ± 10.83, and 108 ± 8.97 beats per min, respectively. Mean standard deviation dispersion perpendicular and along the axis of identity (SD1/SD2) were 0.244 ± 0.038, 0.220 ± 0.022, 0.180 ± 0.050, and 0.167 ± 0.015, respectively. P values for mean HR, max HR, and HRV were significant when comparing SB with TI (0.010, 0.027, and 0.001) and CL (0.007, 0.001, and 0.012) but not when comparing with PR (0.026, 0.125, and 0.321). Comparison of SD1/SD2 for TI versus CL showed no statistical significance, P=0.578. Poincaré plots confirmed the similar patterns of physiologic activation. Subject baseline and PR plots were fan-shaped, suggesting primary parasympathetic input. TI and CL were torpedo-shaped, suggesting sympathetic activation. Conclusion: Study of the biometrics of physicians as they deliver real-time critical patient care is feasible using wearable technology. Critical care activities requiring not only thought, focus, and planning but also the physical execution of technical skills, such as IT or CL insertion, resulted in higher levels of sympathetic activation. Further study of physicians from various specialties and different levels of experience, the use of stress mitigation techniques, and correlation with procedural success or failure is warranted

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.010
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Qualitative · Consensus signal: Qualitative
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.387
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.334
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designQualitative
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Intensive and Critical CareSame topicHeart Rate Variability and Autonomic ControlFrench-language works237,207