MétaCan
Menu
Back to cohort
Record W2809030782 · doi:10.1089/lap.2017.0293

Proof of Concept Study: Investigating Force Metrics of an Intracorporeal Suturing Knot Task

2018· article· en· W2809030782 on OpenAlexaff
Justin Wee, Georges Azzie, James M. Drake, J. Ted Gerstle

Bibliographic record

VenueJournal of Laparoendoscopic & Advanced Surgical Techniques · 2018
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsSickKids FoundationHospital for Sick ChildrenUniversity of Toronto
Fundersnot available
KeywordsMedicineKnot (papermaking)Task forceSurgeryTask (project management)WorkflowMetric (unit)Haptic technologySimulationComputer scienceOperations management

Abstract

fetched live from OpenAlex

BACKGROUND: Mastering proper force manipulation in minimally invasive surgery can take many hours of practice and training. Improper force control can lead to necrosis, infection, and scarring. A force-sensing skin (FSS) has been developed, which measures forces at the distal end of minimal access surgeries' (MAS) instruments without altering the instrument's structural integrity or the surgical workflow, and acts as a minimally disruptive add-on to any MAS instrument. METHODS: A proof of concept study was conducted using a FSS-equipped 5 mm straight-tip needle holder. Participants (n = 19: 3 novices, 11 fellows, and 5 staff surgeons) performed one intracorporeal suturing knot task (ISKT). Using participant task video footage, each participant's two puncture forces (each wall of the Penrose drain) and three knot tightening forces were measured. Force metrics from the three expertise groups were compared using analysis of variance (ANOVA) and Tukey's honest significance test with statistical significance assessed at P < .05. RESULTS: Preliminary ISKT force metric data showed differences between novices and more experienced fellows and surgeons. Of the five stages of the ISKT evaluated, the first puncture force of the Penrose drain seemed to best reflect the difference in skill among participants. The study demonstrated ISKT knot tightening and puncture force ranges across three expertise levels (novices, surgical fellows, and staff surgeons) of 0.586 to 6.089 newtons (N) and 0.852 to 2.915 N, respectively. CONCLUSION: The investigation of force metrics is important for the implementation of future force feedback systems as it can provide real-time information to surgeons in training and the operating theater.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.353
Teacher spread0.318 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Laparoendoscopic & Advanced Surgical TechniquesSame topicSurgical Simulation and TrainingFrench-language works237,207