MétaCan
Menu
Back to cohort
Record W2809483729 · doi:10.4103/jcvjs.jcvjs_143_17

Cadaveric device-injected very high-viscosity cement during vertebroplasty

2018· article· en· W2809483729 on OpenAlexaff
AbdulrahmanD Algarni, Waleed Awwad, Amna Baljoun, Yasir Alabdulkarim, Chung-Hwan Kim, Demitri Giannitsios, Lorne Beckman, Jean Ouellet, Thomas Steffen

Bibliographic record

VenueJournal of Craniovertebral Junction and Spine · 2018
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsMcGill University Health CentreMcGill University
Fundersnot available
KeywordsCadaveric spasmExtravasationMedicineCementCadaverViscosityLumbar vertebraeSurgeryLeakage (economics)Nuclear medicineDentistryLumbarComposite materialMaterials sciencePathology

Abstract

fetched live from OpenAlex

INTRODUCTION: Cement extravasation during vertebroplasty (VP) is the most commonly reported complication. Cement viscosity is considered the single most important predictor of the risk of extravasation. Certainly, injecting high-viscosity cement (HVC) is difficult to utilize in real practice. We invented a new device capable of injecting high-viscosity with ease and at a distance to avoid radiation. The aim of this study is to confirm the efficacy and safety of the new device on cadaveric vertebrae. METHODOLOGY: A 126 osteoporotic vertebral bodies were harvested from cadavers. Eighty vertebrae were included in the study. Computer-randomization software was used to allocate specimens over two main groups, Conventional VP and New Device. Both groups were further subdivided into two subgroups; high-viscosity and low-viscosity. A custom device was used on each vertebra to induce a compression fracture. RESULTS: < 0.001). The mean volume of cement leakage in the low-viscosity group was 0.23 and 0.15 cc, for the Conventional VP and New Device, respectively. In both groups, the most common site for leakage was the vertebral end plate, which was exhibited more in the low-viscosity group (71.5%) compared with the high-viscosity group (42.5%). The preset target amount of cement to be injected was reached in 99% of the time when injecting HVC with the New Device, compared with 62% using the Conventional VP. In both groups, there was no correlation between the amount of cement injected and the amount of leakage. CONCLUSION: The new device is capable of injecting HVC easily, with a lower incidence of cement leakage. It also minimized the risk of radiation exposure to the surgeon.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.776
Threshold uncertainty score0.462

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.258
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Craniovertebral Junction and SpineSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207