MétaCan
Menu
Back to cohort
Record W2811002915 · doi:10.1109/nssmic.2017.8532920

Which is better, a SCoTSS gamma imager, or an ARDUO UAV-borne directional detector?

2017· preprint· en· W2811002915 on OpenAlexaff
A. McCann, L.E. Sinclair, P.R.B. Saull, C. Ouellet, R Fortin, Carolyn Chen, Maurice J. Coyle, R. Mantifel, A.M.L. MacLeod, Reid A. Van Brabant, J L Buckle, Pierre-Luc Drouin, Jens Hovgaard, Bohdan Krupskyy, Blake Beckman, Blaine Fairbrother

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsDefence Research and Development CanadaNational Research Council CanadaNatural Resources Canada
Fundersnot available
KeywordsDetectorScintillatorSilicon photomultiplierOpticsPhysicsField of viewElectromagnetic shieldingTelescopePinhole (optics)Energy (signal processing)

Abstract

fetched live from OpenAlex

The SiPM-based Compton Telescope for Safety and Security (SCoTSS) has been developed with inorganic crystalline scintillator material for gamma detection. The instrument is sensitive enough to be used in a mobile survey mode, accumulating energy deposited in any crystal second-by-second and tagging these spectra with GPS position. The SCoTSS imager of course has the additional advantage of being able to produce an image of the radioactive objects in its field of view using events that satisfy a coincidence trigger between the scatter and absorber layers. The Advanced Radiation Detector for UAV Operations (ARDUO) on the other hand, is a non-imaging directional detector intended for use aboard a small unmanned aerial vehicle (UAV). The ARDUO detector features exactly the same volume of CsI(Tl) as is used in the absorber layer of a single SCoTSS module, giving it similar detection and alarming sensitivity, and mapmaking capability. However, in the ARDUO detector, the crystals are arranged closely together to optimize direction determination from self-shielding effects. Flown in a grid pattern with a UAV over an area of extended contamination, the ARDUO detector is also capable of making a map or image of that area. With its close-packed crystal arrangement, the ARDUO detector makes a poor Compton imager but does have some ability to produce a peripheral image in a fly-by. In this presentation we investigate the relative merits of Compton imaging versus mobile directional detection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.704
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0060.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.304
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes1
Has abstractyes

Explore more

Same topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207