MétaCan
Menu
Back to cohort
Record W2884038440 · doi:10.1016/j.nicl.2018.07.013

Low-dose CT for the spatial normalization of PET images: A validation procedure for amyloid-PET semi-quantification

2018· article· en· W2884038440 on OpenAlexfundno aff
Luca Presotto, Leonardo Iaccarino, Arianna Sala, Emilia Giovanna Vanoli, Cristina Muscio, Anna Nigri, Maria Grazia Bruzzone, Fabrizio Tagliavini, Luigi Gianolli, Daniela Perani, Valentino Bettinardi

Bibliographic record

VenueNeuroImage Clinical · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsnot available
FundersMinistry of Health, British ColumbiaMinistero della Salute
KeywordsPositron emission tomographyNormalization (sociology)Nuclear medicineSpatial normalizationCorrection for attenuationNeuroimagingMagnetic resonance imagingStandardized uptake valuePET-CTMedicineArtificial intelligencePattern recognition (psychology)RadiologyComputer science

Abstract

fetched live from OpenAlex

The reference standard for spatial normalization of brain positron emission tomography (PET) images involves structural Magnetic Resonance Imaging (MRI) data. However, the lack of such structural information is fairly common in clinical settings. This might lead to lack of proper image quantification and to evaluation based only on visual ratings, which does not allow research studies or clinical trials based on quantification. PET/CT systems are widely available and CT normalization procedures need to be explored. Here we describe and validate a procedure for the spatial normalization of PET images based on the low-dose Computed Tomography (CT) images contextually acquired for attenuation correction in PET/CT systems. We included N = 34 subjects, spanning from cognitively normal to mild cognitive impairment and dementia, who underwent amyloid-PET/CT (18F-Florbetaben) and structural MRI scans. The proposed pipeline is based on the SPM12 unified segmentation algorithm applied to low-dose CT images. The validation of the normalization pipeline focused on 1) statistical comparisons between regional and global 18F-Florbetaben-PET/CT standardized uptake value ratios (SUVrs) estimated from both CT-based and MRI-based normalized PET images (SUVrCT, SUVrMRI) and 2) estimation of the degrees of overlap between warped gray matter (GM) segmented maps derived from CT- and MRI-based spatial transformations. We found negligible deviations between regional and global SUVrs in the two CT and MRI-based methods. SUVrCT and SUVrMRI global uptake scores showed negligible differences (mean ± sd 0.01 ± 0.03). Notably, the CT- and MRI-based warped GM maps showed excellent overlap (90% within 1 mm). The proposed analysis pipeline, based on low-dose CT images, allows accurate spatial normalization and subsequent PET image quantification. A CT-based analytical pipeline could benefit both research and clinical practice, allowing the recruitment of larger samples and favoring clinical routine analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.732
Threshold uncertainty score0.554

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.082
GPT teacher head0.425
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueNeuroImage ClinicalSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207