MétaCan
Menu
Back to cohort
Record W2884236052 · doi:10.1093/cvr/cvy182

Cardiac resynchronization is pro-arrhythmic in the absence of reverse ventricular remodelling: a systematic review and meta-analysis

2018· review· en· W2884236052 on OpenAlexaff
Bishoy Deif, Brennan Ballantyne, Fahad Almehmadi, M. Mikhail, Jaimie Manlucu, Raymond Yee, John L. Sapp, Jason D. Roberts, Jeff S. Healey, Peter Leong‐Sit, Anthony Tang

Bibliographic record

VenueCardiovascular Research · 2018
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsDalhousie UniversityQueen Elizabeth II Health Sciences CentreMcMaster UniversityPopulation Health Research InstituteWestern University
Fundersnot available
KeywordsCardiac resynchronization therapyMedicineCardiologyInternal medicineImplantable cardioverter-defibrillatorHeart failureConfidence intervalMeta-analysisRelative riskProspective cohort studyRetrospective cohort studyCohortEjection fraction

Abstract

fetched live from OpenAlex

Aims: Cardiac resynchronization therapy (CRT) has been shown to reduce mortality and heart failure (HF) hospitalization but its effects on the rate of ventricular arrhythmias (VAs) appears to be neutral. We hypothesize that CRT with LV epicardial stimulation is inherently pro-arrhythmic and increases VA rates in the absence of reverse ventricular remodelling while conferring an anti-arrhythmic effect in mechanical responders. Methods and results: In this systematic review and meta-analysis, we considered retrospective cohort, prospective cohort, and randomized controlled trials comparing VA rates between cardiac resynchronization therapy-defibrillator (CRT-D) non-responders, CRT-D responders and those with implantable cardioverter-defibrillator (ICD) only. Studies were eligible if they defined CRT-D responders using a discrete left ventricular volumetric value as assessed by any imaging modality. Studies were identified through searching electronic databases from their inception to July 2017. We identified 2579 citations, of which 23 full-text articles were eligible for final analysis. Our results demonstrated that CRT-D responders were less likely to experience VA than CRT-D non-responders, relative risk (RR) 0.49 [95% confidence interval (CI) 0.41-0.58, P < 0.01] and also less than patients with ICD only: RR 0.59 (95% CI 0.50-0.69, P < 0.01). However, CRT-D mechanical non-responders had a greater likelihood of VA compared with ICD only, RR 0.76 (95% CI 0.63-0.92, P = 0.004). Conclusion: CRT-D non-responders experienced more VA than CRT-D responders and also more than those with ICD only, suggesting that CRT with LV epicardial stimulation may be inherently pro-arrhythmic in the absence of reverse remodelling.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.680
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0180.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0130.012
Bibliometrics0.0010.006
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.279
GPT teacher head0.440
Teacher spread0.161 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueCardiovascular ResearchSame topicCardiac pacing and defibrillation studiesFrench-language works237,207