MétaCan
Menu
Back to cohort
Record W2885050819 · doi:10.1088/1361-6560/aad7e2

Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP)

2018· article· en· W2885050819 on OpenAlexafffund
Nolan Esplen, Lila Chergui, Christopher Johnstone, Magdalena Bazalova‐Carter

Bibliographic record

VenuePhysics in Medicine and Biology · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Victoria
FundersNational Research Council CanadaNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsWestern Canada Research Grid
KeywordsCollimatorMicrobeamMaterials scienceCollimated lightMonte Carlo methodOpticsImaging phantomBeam (structure)Nuclear medicineRadiationPhysicsMedicineMathematics

Abstract

fetched live from OpenAlex

Abstract Microbeam radiation therapy (MRT) is a pre-clinical, spatially-fractionated treatment modality noted for its ability to achieve a large differential response between normal and tumoral tissues. In the present study, TOPAS Monte Carlo (MC) simulations were used to optimize the design of a compact, affordable multi-slit collimator (MSC) suitable for use with the small animal radiation research platform (SARRP). MRT dose distributions in a (1 × 1 × 3)cm 3 water phantom were simulated for a tungsten MSC using different focal spot sizes (0.4, 3 mm), beam energies (40, 80, 220 kVp), slit widths (100, 125, 150, 175, 200 µ m), collimator thicknesses (1.5, 2.5, 3 cm) and collimator-to-surface distances (CSD of 1 and 3 cm). Key MRT figures of merit, namely the peak-to-valley dose ratio (PVDR), full-width at half-maximum and peak dose rate were determined. Use of the small focal spot maximized the PVDR (~40 at surface) and reduced the system’s sensitivity to changes in CSD, but decreased the collimated beam output to 55.2 cGy min −1 . The large focal spot was ill-suited for large CSD irradiations, but increased the beam output by a factor of 2.8, to 153.0 cGy min −1 , and decreased the sensitivity to changes in slit width. A modular MSC, using divergent plastic spacer materials in place of excavated slits, was also investigated. Polypropylene and polyethylene terephthalate material spacers were considered and while neither reduced the PVDR compared to air slits, the dose rate was reduced by 37% and 47%, respectively. Lastly, a steel parallel-slit MSC was used in a preliminary test of MRT delivery using the SARRP. Discrepancies between the results of film dosimetry and the corresponding MC simulations highlight the need to fabricate a more well-defined collimator for use in future validation and radiobiological work. The simulated results of this study are being used to inform the design of such a collimator, which will additionally boast a high degree of modularity at reasonable cost.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.351
GPT teacher head0.439
Teacher spread0.088 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2018
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207