MétaCan
Menu
Back to cohort
Record W2888637943 · doi:10.1002/mp.13148

The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator

2018· article· en· W2888637943 on OpenAlexafffundabout
Logan Montgomery, Michael D. Evans, Liheng Liang, Robert Maglieri, J. Kildea

Bibliographic record

VenueMedical Physics · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsJewish General HospitalMcGill University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsTruebeamLinear particle acceleratorNeutronFluenceBremsstrahlungNeutron fluxPhysicsBeam (structure)Neutron captureNuclear physicsNuclear medicineOpticsIrradiationElectronMedicine

Abstract

fetched live from OpenAlex

Purpose Neutrons are an unavoidable by‐product of high‐energy radiation therapy treatments that deliver unwanted nontarget dose to patients. Use of flattening‐filter‐free (FFF) photon beams has been shown to significantly reduce photoneutron production per monitor unit (MU) of dose delivered. The purpose of this investigation was to characterize the photoneutron production of the 10 MV and 10 MV FFF beams of the Varian TrueBeam TM linear accelerator. Methods Neutron fluence spectra were measured using a Nested Neutron Spectrometer TM (NNS, Detec Inc., Gatineau, Canada). The ratios of neutron fluence and ambient dose equivalent for the 10 MV FFF beam relative to the 10 MV beam, dubbed FF‐ratios (FFF/FF), were used to characterize the difference between the two beams. FF‐ratios were compared under the following three conditions (a) per MU, at various locations in the treatment room, (b) per MU, with the linac jaws opened and closed, and (c) per electron striking the bremsstrahlung target, as opposed to per MU, at one location with the jaws closed. Results On average, the neutron fluence for the 10 MV FFF beam was 37% lower per MU than the 10 MV beam (FF‐ratio = 0.63). The FF‐ratio in neutron fluence and ambient dose equivalent did not vary by much between different locations within the treatment room. However, the FF‐ratio in neutron ambient dose equivalent was reduced significantly when the linac jaws were opened compared to closed, which implies that the jaws contribute more to the photoneutron spectrum of the 10 MV FFF beam than to the 10 MV beam. Finally, it was found that the 10 MV FFF beam produces more photoneutrons per electron striking the bremsstrahlung target than the 10 MV beam (FF‐ratio = 2.56). Conclusions The photoneutron fluence per MU produced by the 10 MV FFF beam is 37% lower than the 10 MV beam of a Varian TrueBeam linac. Accordingly, a reduction in neutron dose received by patients is achieved through use of the unflattened beam, provided that treatment plans for each beam require approximately the same number of MU. It was found to be instructive to compare the photoneutron yield per source electron between the two beams as it helped provide an understanding of the physics underlying photoneutron production in both beams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.877
Threshold uncertainty score0.251

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.280
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2018
Admission routes3
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207