MétaCan
Menu
Back to cohort
Record W2888881362 · doi:10.1002/mp.13153

Inverse optimization of low‐cost kilovoltage x‐ray arc therapy plans

2018· article· en· W2888881362 on OpenAlexafffundabout
Dylan Y. Breitkreutz, Marc‐André Renaud, Jan Seuntjens, M Weil, Sergei Zavgorodni, Magdalena Bazalova‐Carter

Bibliographic record

VenueMedical Physics · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencyMcGill UniversityUniversity of Victoria
FundersWestern Canada Research Grid
KeywordsNuclear medicineMedicineRadiation treatment planningProstateDosimetryRadiation therapyProstate cancerMedical physicsRadiologyCancer

Abstract

fetched live from OpenAlex

PURPOSE: The objective of this work was to investigate the benefits of using inverse optimization treatment planning for kilovoltage arc therapy (KVAT) and to assess the dosimetric limitations of KVAT. METHODS: Monte Carlo (MC) calculated, inversely optimized KVAT plans of spherical, idealized breast, lung, and prostate lesions were calculated using the EGSnrc/BEAMnrc and DOSXYZnrc MC codes. The dose delivered with the KVAT system, which generates 200-225 kV photon beamlets, was calculated and inversely optimized using an optimization framework developed at McGill University. KVAT dose distributions were compared with inversely optimized and MC generated megavoltage (MV) volumetric modulated arc therapy (VMAT) plans as a reference. Prescription doses delivered to 95% of the planning target volume (PTV) were 38.5 (10 fractions), 60 (30 fractions) and 73.8 (41 fractions) Gy for the breast, lung and prostate patients, respectively. Dose distributions, dose volume histograms, and PTV homogeneity indices were used to evaluate KVAT and VMAT plans based on RTOG protocols. RESULTS: All organ-at-risk (OAR) doses were within prescribed dose limits for KVAT and VMAT plans. Generally, KVAT plans delivered higher doses to OARs. For example, due to the lower energy of KVAT, 50% of the rib volume received 12.9 Gy from KVAT while only receiving 2.5 Gy from VMAT. OAR doses were especially high for the KVAT prostate plan due to the presence of large volumes of bony anatomy, which illustrates a limitation of the KVAT system. The KVAT treatment times per fraction for the breast, lung and prostate patients were 2.8, 2.6 and 5.5 min, respectively. CONCLUSIONS: The inversely optimized KVAT plans presented in this work have demonstrated the ability of our novel low-cost, kilovoltage x-ray therapy system to safely treat deep-seated spherical lesions in breast and lung patients while meeting RTOG dose constraints on OARs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.281
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes3
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207