MétaCan
Menu
Back to cohort
Record W2889609069 · doi:10.1136/thoraxjnl-2017-211466

Accuracy and precision of transcutaneous carbon dioxide monitoring: a systematic review and meta-analysis

2018· review· en· W2889609069 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueThorax · 2018
Typereview
Languageen
FieldMedicine
TopicReconstructive Facial Surgery Techniques
Canadian institutionsUniversity of TorontoUniversity Health Network
FundersNational Health and Medical Research CouncilMedical Research CouncilDepartment of Health and Aged Care, Australian GovernmentAustralian Government
KeywordsMedicineEarlobeLimits of agreementMeta-analysisPopulationSystematic errorAccuracy and precisionContext (archaeology)Carbon dioxideStatisticsSurgeryNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

Background Transcutaneous carbon dioxide (TcCO 2 ) monitoring is a non-invasive alternative to arterial blood sampling. The aim of this review was to determine the accuracy and precision of TcCO 2 measurements. Methods Medline and EMBASE (2000–2016) were searched for studies that reported on a measurement of PaCO 2 that coincided with a measurement of TcCO 2 . Study selection and quality assessment (using the revised Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2)) were performed independently. The Grading Quality of Evidence and Strength of Recommendation approach was used to summarise the strength of the body of evidence. Pooled estimates of the mean bias between TcCO 2 and PaCO 2 and limits of agreement with outer 95% CIs (termed population limits of agreement) were calculated. Results The mean bias was −0.1 mm Hg and the population limits of agreement were −15 to 15 mm Hg for 7021 paired measurements taken from 2817 participants in 73 studies, which was outside of the clinically acceptable range (7.5 mm Hg). The lowest PaCO 2 reported in the studies was 18 mm Hg and the highest was 103 mm Hg. The major sources of inconsistency were sensor location and temperature. The population limits of agreement were within the clinically acceptable range across 3974 paired measurements from 1786 participants in 44 studies that applied the sensor to the earlobe using the TOSCA and Sentec devices (−6 to 6 mm Hg). Conclusion There are substantial differences between TcCO 2 and PaCO 2 depending on the context in which this technology is used. TcCO 2 sensors should preferentially be applied to the earlobe and users should consider setting the temperature of the sensor higher than 42°C when monitoring at other sites. Systematic review registration number PROSPERO; CRD42017057450.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.795
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0130.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.403
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it