MétaCan
Menu
Back to cohort
Record W2889829193 · doi:10.1371/journal.pone.0196945

Improving the SIENA performance using BEaST brain extraction

2018· article· en· W2889829193 on OpenAlexafffund
Kunio Nakamura, Simon Fristed Eskildsen, Sridar Narayanan, Douglas L. Arnold, D. Louis Collins

Bibliographic record

VenuePLoS ONE · 2018
Typearticle
Languageen
FieldComputer Science
TopicMedical Image Segmentation Techniques
Canadian institutionsNeuroRx Research (Canada)McGill UniversityMontreal Neurological Institute and Hospital
FundersGenentechNational Institutes of HealthMitacsEisaiNational Institute of Biomedical Imaging and BioengineeringCanadian Institutes of Health ResearchEli Lilly and CompanyU.S. Department of DefenseCompute CanadaNorthern California Institute for Research and EducationAcorda TherapeuticsMcGill UniversityPfizerBiogenBioClinicaSanofi GenzymeF. Hoffmann-La RocheUniversity of Southern CaliforniaSanofiAlzheimer's Disease Neuroimaging InitiativeBristol-Myers SquibbNational Institute on AgingAlzheimer's AssociationFoundation for the National Institutes of Health
KeywordsReproducibilityBrain sizeMedicineSegmentationNuclear medicineMagnetic resonance imagingMathematicsComputer scienceArtificial intelligenceStatisticsRadiology

Abstract

fetched live from OpenAlex

We present an improved image analysis pipeline to detect the percent brain volume change (PBVC) using SIENA (Structural Image Evaluation, using Normalization, of Atrophy) in populations with Alzheimer's dementia. Our proposed approach uses the improved brain extraction mask from BEaST (Brain Extraction based on nonlocal Segmentation Technique) instead of the conventional BET (Brain Extraction Tool) for SIENA. We compared four varying options of BET as well as BEaST and applied these five methods to analyze scan-rescan MRIs in ADNI from 332 subjects, longitudinal ADNI MRIs from the same 332 subjects, their repeat scans over time, and OASIS longitudinal MRIs from 123 subjects. The results showed that BEaST brain masks were consistent in scan-rescan reproducibility. The cross-sectional scan-rescan error in the absolute percent brain volume difference measured by SIENA was smallest (p≤0.0187) with the proposed BEaST-SIENA. We evaluated the statistical power in terms of effect size, and the best performance was achieved with BEaST-SIENA (1.2789 for ADNI and 1.095 for OASIS). The absolute difference in PBVC between scan-dataset (volume change from baseline to year-1) and rescan-dataset (volume change from baseline repeat scan to year-1 repeat scan) was also the smallest with BEaST-SIENA compared to the BET-based SIENA and had the highest correlation when compared to the BET-based SIENA variants. In conclusion, our study shows that BEaST was robust in terms of reproducibility and consistency and that SIENA's reproducibility and statistical power are improved in multiple datasets when used in combination with BEaST.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.357
Threshold uncertainty score0.189

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.283
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2018
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicMedical Image Segmentation TechniquesFrench-language works237,207