MétaCan
Menu
← Back to cohort
Record W2890333483 · doi:10.71781/26136

Impact des biais introduits lors de différents types de mesures de pression artérielle

2017· dissertation· fr· W2890333483 on OpenAlexaboutno aff
Félix Rinfret

Bibliographic record

VenueOpen MIND · 2017
Typedissertation
Languagefr
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsnot available
Fundersnot available
KeywordsPhysicsGynecologyMedicine

Abstract

fetched live from OpenAlex

L’hypertension artérielle (HTA) est un facteur de risque cardiovasculaire majeur et touche environ le quart des adultes canadiens. Le diagnostic de la maladie, son traitement et son suivi reposent tous sur la mesure de la pression artérielle. Différentes méthodes de mesure de pression artérielle existent et sont même complémentaires quant à certains aspects. Ces méthodes incluent entre autres la mesure manuelle de la pression artérielle, la mesure de la pression artérielle en clinique – oscillométrique en série (MPAC-OS) et la mesure de la pression artérielle à domicile (MPAD). Afin d’optimiser adéquatement la gestion de l’HTA, les mesures réalisées doivent être exactes et exemptes de biais. Le présent mémoire aborde trois biais potentiels et cherche à quantifier leurs impacts. Ces biais sont : le biais existant entre une mesure manuelle réalisée dans des conditions optimales et la MPAC-OS, le biais existant dans des calendriers de MPAD incomplets et le biais existant entre deux appareils différents de MPAC-OS dans des environnements cliniques différents. Premièrement, il a été démontré que lorsque la mesure manuelle est effectuée de façon protocolaire par une infirmière bien formée, il n’existe pas de différence considérée comme cliniquement significative entre la mesure manuelle auscultatoire et la MPAC-OS. Deuxièmement, il a été démontré dans une seconde étude que les calendriers incomplets de 28 mesures de MPAD ont un impact sur la précision et la validité diagnostique par rapport au calendrier complet. Bien qu’il n’existe pas de limites claires, nos données suggèrent qu’un minimum de 21 mesures sur les 28 mesures possibles offre une précision et une validité diagnostique presque parfaites. Finalement, il a été démontré dans notre dernière étude que deux appareils de MPAC-OS différents, l’Omron HEM-907 et le BpTRU BPM-100 sont relativement équivalents dans les zones de pression artérielle autour des seuils diagnostiques. Par contre, lorsque les pressions estimées sont basses, les appareils tendent à avoir des différences cliniquement et statistiquement significatives.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.011
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0060.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.406
Teacher spread0.346 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueOpen MIND→Same topicBlood Pressure and Hypertension Studies→French-language works237,207→