MétaCan
Menu
Back to cohort
Record W2890739226 · doi:10.1109/jtehm.2018.2866105

Design and Integration of an Inexpensive Wearable Mechanotactile Feedback System for Myoelectric Prostheses

2018· article· en· W2890739226 on OpenAlexafffund
Katherine R. Schoepp, Michael R. Dawson, Jonathon S. Schofield, Jason P. Carey, Jacqueline S. Hebert

Bibliographic record

VenueIEEE Journal of Translational Engineering in Health and Medicine · 2018
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsGlenrose Rehabilitation HospitalUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaAlberta InnovatesGlenrose Rehabilitation Hospital FoundationTrue Patriot Love Foundation
KeywordsModular designGRASPComputer scienceWearable computerProsthesisSensory systemProsthetic handHuman–computer interactionSimulationEmbedded systemArtificial intelligence

Abstract

fetched live from OpenAlex

The aim of this paper was to demonstrate the functionality of an inexpensive mechanotactile sensory feedback system for transhumeral myoelectric prostheses. We summarize the development of a tactile-integrated prosthesis, including 1) evaluation of sensors that were retrofit onto existing commercial terminal devices; 2) design of two custom mechanotactile tactors that were integrated into a socket without compromising suction suspension; 3) design of a modular controller which translated sensor input to tactor output, was wirelessly adjusted, and fit within a prosthetic forearm; and 4) evaluation of the system with a single transhumeral participant. Prosthesis functionality was demonstrated over three test sessions; the participant was able to identify tactor stimulation location and demonstrated a reduction in grasp force with the mechanotactile stimulation. This system offers an inexpensive and modular solution for integration of a mechanotactile sensory feedback system into a prosthetic socket without compromising the suction seal. These principles can be applied in future studies to investigate the direct impact of sensory feedback on tangible outcomes for prosthetic users, thereby reducing barriers to clinical translation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.268
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations47
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Journal of Translational Engineering in Health and MedicineSame topicMuscle activation and electromyography studiesFrench-language works237,207