MétaCan
Menu
Back to cohort
Record W2890888642 · doi:10.1088/1361-6560/aae24f

A multi-criteria optimization approach for HDR prostate brachytherapy: II. Benchmark against clinical plans

2018· article· en· W2890888642 on OpenAlexafffund
Songye Cui, Philippe Després, Luc Beaulieu

Bibliographic record

VenuePhysics in Medicine and Biology · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversité Laval
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsBenchmark (surveying)BrachytherapyComputer scienceRadiation treatment planningPlan (archaeology)Process (computing)Prostate brachytherapyMathematical optimizationQuality assuranceMedical physicsAlgorithmRadiologyMathematicsMedicineRadiation therapyOperations managementEngineering

Abstract

fetched live from OpenAlex

Abstract The current iterative approach to inverse planning of high dose rate treatment planning can be time consuming. The purpose of this two-part study is to streamline the planning process while maintaining plan quality. In this second part, a multi-criteria optimization (MCO) planning algorithm is proposed and benchmarked against a standard planning algorithm. With a set of previously established regression models, a patient-specific valid solution space on the Pareto surface was predicted based on the anchor plans results. Alternative plans generated alongside the partial Pareto front were presented to the planner, and one plan was selected as the MCO plan. The dosimetric parameters results as well as the planning time were compared between the MCO plans and the physician-approved standard plans for 236 prostate cases. Results show that the urethra is better spared with MCO planning than with standard planning (a lower mean urethral D 10 value of 2.25%). The overall MCO plan quality also outperforms the standard plan quality, since MCO planning is able to increase the frequency of clinically acceptable plans meeting all of RTOG criteria simultaneously without any human intervention (from 83.05% to 97.46%). Finally, the average MCO planning time is without any interventions of treatment planners. The presented MCO planning algorithm constitutes a robust and automated way to improve treatment quality in brachytherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.151
GPT teacher head0.446
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2018
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207