Dosimetry of small static fields used in external photon beam radiotherapy: Summary of TRS‐483, the IAEA–AAPM international Code of Practice for reference and relative dose determination
Bibliographic record
Abstract
PURPOSE: A joint IAEA/AAPM international working group has developed a Code of Practice (CoP) for the dosimetry of small static fields used in external megavoltage photon beam radiotherapy, published by the IAEA as TRS-483. This summary paper introduces and outlines the main aspects of the CoP. METHODS: IAEA TRS-483 is a condensation of the wide range of different approaches that have been described in the literature for the reference dosimetry of radiotherapy machines with nominal accelerating potential up to 10 MV that cannot establish the conventional 10 cm × 10 cm reference field, and for the determination of field output factors for relative dosimetry in small static photon fields. The formalism used is based on that developed by Alfonso et al. [Med Phys. 2008;35:5179-5186] for this modality. RESULTS: Three introductory sections describe the rationale and context of the CoP, the clinical use of small photon fields, and the physics of small-field dosimetry. In the fourth section, definitions of terms that are specific to the CoP (as compared to previous CoPs for broad-beam reference dosimetry, such as IAEA TRS-398 and AAPM TG-51) are given; this section includes a list of the symbols and equivalences between IAEA and AAPM nomenclature to facilitate the practical implementation of the CoP by end users of IAEA TRS-398 and AAPM TG-51. The fifth section summarizes the equations and procedures that are recommended in the CoP and the sixth section provides an overview of the methods used to derive the data provided in IAEA TRS-483. CONCLUSIONS: This is the first time an international Code of Practice for the dosimetry of small photon fields based on comprehensive data and correction factors has been published. This joint IAEA/AAPM CoP will ensure consistent reference dosimetry traceable to the international System of Units and enable common and internationally harmonized procedures to be followed by radiotherapy centers worldwide for the dosimetry of small static megavoltage photon fields.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.009 | 0.014 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.005 | 0.005 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.002 | 0.001 |
| Open science | 0.002 | 0.002 |
| Research integrity | 0.001 | 0.002 |
| Insufficient payload (model declined to judge) | 0.004 | 0.003 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".