MétaCan
Menu
Back to cohort
Record W2894220094 · doi:10.1109/icd.2018.8470213

End Winding Protections Improvements Helping To Downsize dV/dt Filter For Medium Voltage Machine Fed By NPP Multi-Levels VSI Drive

2018· article· en· W2894220094 on OpenAlexaff
Weijun Yin, Lionel Durantay, Lili Zhang, Saeed Ul Haq, Francois Vannay

Bibliographic record

Venue2018 IEEE 2nd International Conference on Dielectrics (ICD) · 2018
Typearticle
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsGeneral Electric (Canada)
Fundersnot available
KeywordsStatorVoltageElectrical engineeringInverterHigh voltagePower electronicsCorona ringStress (linguistics)Filter (signal processing)Computer scienceEngineeringTopology (electrical circuits)Materials scienceCorona discharge

Abstract

fetched live from OpenAlex

In recent years, a growth trend is evident in power electronics from Load Commutated Inverter to Voltage Source Inverter drives based on Neutral Point Piloted 5-levels topology up to 15kV using fast switching devices for better efficiency and compactness. However, a dV/dt filter is required to avoid fast insulation degradation of the motor when exposed to rapid rise repetitive impulses voltage from the Drive. Especially in the ending winding region where preeminent electrical stress is localized toward the slot exit with fast rise time of pulsed voltage. For dV/dt above 3kV/us, traditional corona protection method using conventional stress grading tape is no longer sufficient to prevent the surface discharge and excessive heating at the slot exit. Numerical simulation established in multi-physics finite element analysis indicates that electrical stress distribution and power dissipation at the end winding is closely related to the rise time of drive pulses and stress grading materials properties. New corona protection method is developed based on modeling results and validated on real stator bars under fast pulses. This paper will describe the typical dV/dt patterns generated by those multilevels drives impacting the dV/dt filter and the system of insulation of medium voltage machine. It will also discuss the effectiveness of end winding surface discharge prevention by proper stress grading design and materials selection under high stresses of dV/dt.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.316
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2018
Admission routes1
Has abstractyes

Explore more

Same venue2018 IEEE 2nd International Conference on Dielectrics (ICD)Same topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207