MétaCan
Menu
Back to cohort
Record W2894846036

Bioaktywne powłoki przeciwdrobnoustrojowe na wyrobach medycznych do implantacji nałożone przez plazmowe utlenianie elektrolityczne

2018· article· pl· W2894846036 on OpenAlexaff
D. Dzhurinskiy

Bibliographic record

VenueObróbka Plastyczna Metali · 2018
Typearticle
Languagepl
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsUniversity of Windsor
Fundersnot available
KeywordsMaterials scienceScanning electron microscopeCoatingAqueous solutionFourier transform infrared spectroscopyChemical engineeringPlasma electrolytic oxidationNanoparticleNuclear chemistrySurface modificationPotassium hydroxideElectrolyteNanotechnologyComposite materialChemistryOrganic chemistry
DOInot available

Abstract

fetched live from OpenAlex

In the present study, a novel TiO2-based coating containing nanosized hydroxyapatite (n-HA) and Silver particles has been formed on commercially available Ti-6Al-4V (Grade 5) and Ti-pure (Grade 2) alloy substrates by the Plasma Electrolytic Oxidation (PEO) technique. The coating deposition were provided in an aqueous solution of disodium hydrogen phosphate containing suspended hydroxyapatite nanoparticles and potassium hydroxide under a pulsed bipolar current mode with controlled duty cycle. Inclusion of antimicrobial silver particles were possible from a separate technological operation in AgNO3 aqueous solution by the principle of photocatalysis at TiO2 surface under ultraviolet treatment. The surface morphology of the formed coatings has been examined by Scanning Electron Microscopy (SEM), while the element composition of the coatings has been determined by Energy Dispersive X-ray analysis (EDS). The presence of HA nanoparticles within the formed coatings has been analyzed by Fourier Transform Infrared Spectroscopy (FTIR). The results indicate that the formed PEO coatings exhibit a porous network structure with embedded n-HA and Ag particles uniformly distributed over the entire surface of the coatings. The PEO-formed TiO2:n-HA:Ag layers can be used as a bioactive biomimetic coating with antimicrobial properties to enhance surface bioactivity, osseointegration and biochemical stability in implantable medical devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.227
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueObróbka Plastyczna MetaliSame topicBone Tissue Engineering MaterialsFrench-language works237,207