MétaCan
Menu
← Back to cohort
Record W2895480531 · doi:10.5194/amt-2018-329

Characterization of lower-cost medium precision atmospheric CO <sub>2</sub> monitoring systems for urban areas using commercial NDIR sensors

2018· article· en· W2895480531 on OpenAlexaff
E. Arzoumanian, Felix Vogel, Ana Bastos, Bakhram Gaynullin, Olivier Laurent, Michel Ramonet, Philippe Ciais

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEnvironmental Science
TopicAtmospheric and Environmental Gas Dynamics
Canadian institutionsEnvironment and Climate Change Canada
FundersEIT Climate-KICUniversité de Versailles Saint-Quentin-en-Yvelines
KeywordsCalibrationEnvironmental scienceRemote sensingAccuracy and precisionAtmospheric pressureObservational errorMeteorologyStatisticsMathematicsPhysicsGeography

Abstract

fetched live from OpenAlex

Abstract. CO2 emission estimates from urban areas can be obtained with a network of in-situ instruments measuring atmospheric CO2 combined with high-resolution (inverse) transport modeling. The distribution of CO2 emissions being highly heterogeneous in space and variable in time in urban areas, gradients of atmospheric CO2 need to be measured by numerous instruments placed at multiple locations around and possibly within these urban areas, which calls for the development of lower-cost medium precision sensors to allow a deployment at required densities. Medium precision is here set to be a random error (uncertainty) on hourly measurements of ±1 ppm or less, a precision requirement based on previous studies of network design in urban areas. Here we present tests of a HPP commercial NDIR sensors manufactured by Senseair AB performed in the laboratory and at actual field stations, the latter for CO2 concentration in the Paris area. The lower-cost medium precision sensors are shown to be sensitive to atmospheric pressure and temperature conditions. The sensors respond linearly to CO2 when measuring calibration tanks, but the regression slope between measured and true CO2 differs between individual sensors and changes with time. In addition to pressure and temperature variations, humidity impacts the measurement of CO2, all causing systematic errors. In the field, an empirical calibration strategy is proposed based on parallel measurements with the lower-cost medium precision sensors and a high-precision instrument cavity ring-down instrument during 6 month. This empirical calibration method consists of using a multiple regression approach to create a model of the errors defined as the difference of CO2 measured by the lower-cost medium precision sensors relative to a calibrated high-precision instrument, based on predictors of air temperature, pressure and humidity. This error model shows good performances to explain the observed drifts of the lower-cost medium precision sensors on time scales of up to 1–2 months when trained against 1–2 weeks of high-precision instrument time series. Residual errors are contained within the ±1 ppm target, showing the feasibility to use networks of HPP instruments for urban CO2 networks, provided that they could be regularly calibrated against one anchor reference high-precision instrument.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.235
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2018
Admission routes1
Has abstractyes

Explore more

Same topicAtmospheric and Environmental Gas Dynamics→French-language works237,207→