MétaCan
Menu
Back to cohort
Record W2896523245 · doi:10.1002/mrm.27517

Respiratory‐ and cardiac motion‐corrected simultaneous whole‐heart PET and dual phase coronary MR angiography

2018· article· en· W2896523245 on OpenAlexfundno aff
Camila Muñoz, Radhouène Neji, Karl Kunze, Stephan G. Nekolla, René M. Botnar, Claudia Prieto

Bibliographic record

VenueMagnetic Resonance in Medicine · 2018
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsnot available
FundersCentre For Medical Engineering, King’s College LondonImperial Oil LimitedKing's College LondonEngineering and Physical Sciences Research CouncilNational Institute for Health and Care ResearchWellcome TrustEPSRC Centre for Doctoral Training in Medical ImagingKing’s College LondonWellcomeImperial College LondonHealth ResearchMedical Research Council
KeywordsMedicineCardiac cycleCoronary artery diseaseNuclear medicineCardiologyRadiologyInternal medicine

Abstract

fetched live from OpenAlex

Purpose To develop a framework for efficient and simultaneous acquisition of motion‐compensated whole‐heart coronary MR angiography (CMRA) and left ventricular function by MR and myocardial integrity by PET on a 3T PET‐MR system. Methods An acquisition scheme based on a dual‐phase CMRA sequence acquired simultaneously with cardiac PET data has been developed. The framework is integrated with a motion‐corrected image reconstruction approach, so that non‐rigid respiratory and cardiac deformation fields estimated from MR images are used to correct both the CMRA (respiratory motion correction for each cardiac phase) and the PET data (respiratory and cardiac motion correction). The proposed approach was tested in a cohort of 8 healthy subjects and 6 patients with coronary artery disease. Left ventricular (LV) function estimated from motion‐corrected dual‐phase CMRA was compared to the gold standard estimated from a stack of 2D CINE images for the healthy subjects. Relative increase of signal in motion‐corrected PET images compared to uncorrected images was computed for standard 17‐segment polar maps for each patient. Results Motion‐corrected dual‐phase CMRA images allow for visualization of the coronary arteries in both systole and diastole for all healthy subjects and cardiac patients. LV functional indices from healthy subjects result in good agreement with the reference method, underestimating stroke volume by 3.07 ± 3.26 mL and ejection fraction by 0.30 ± 1.01%. Motion correction improved delineation of the myocardium in PET images, resulting in an increased 18 F‐FDG signal of up to 28% in basal segments of the myocardial wall compared to uncorrected images. Conclusion The proposed motion‐corrected dual‐phase CMRA and cardiac PET produces co‐registered good quality images in both modalities in a single efficient examination of ~13 min.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.558
Threshold uncertainty score0.690

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.318
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207