MétaCan
Menu
Back to cohort
Record W2897004797 · doi:10.1111/aos.13951

Inconsistent distortion in ultra‐widefield fundus image

2018· letter· en· W2897004797 on OpenAlexaboutno aff
Danson Vasanthan Muttuvelu, Jens Folke Kiilgaard

Bibliographic record

VenueActa Ophthalmologica · 2018
Typeletter
Languageen
FieldMedicine
TopicRetinal Diseases and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsFundus (uterus)OphthalmologyDistortion (music)OpticsOptometryMedicinePhysicsOptoelectronics

Abstract

fetched live from OpenAlex

While the advantages of modern ultra-widefield imaging based on ellipsoidal-mirror-SLO-techniques are evident, these images emphasize the need for raising awareness in Optos® image interpretation, particularly when precision and reproducibility of the content is critical, for example, in choroidal naevus follow-up. It is well known from cartography that projecting the surface of a 3D globe to a 2D image causes stretching of the projected image, for example, Greenland and Canada appear larger on the world maps. Similar findings may be assumed in ultra-widefield fundus imaging. There is only one study regarding this entity, and it demonstrates horizontal stretching in Optos® images compared to conventional images (Nicholson et al. 2016). However, in their study, the stretching of the image appears to be in the horizontal plane and evenly distributed. We here report a case that demonstrates a nonlinear distortion within the Optos® image. A 74-year-old woman presents for choroidal naevus follow-up. It appeared as the choroidal naevus was shrunken at the Optos® Image (Fig. 1A) compared to the previous visit (Fig. 1B). Subsequently, traditional fundus colour image (Zeiss FF450plus, Zeiss, Germany) and OCT-image (Heidelberg Spectralis OCT: Heidelberg Engineering, Heidelberg, Germany) were taken. Size and location of the choroidal naevus in the images were compared. In contrast to Optos® images, traditional fundus image and OCT scans showed no change in naevus size or location. More detailed examination of the Optos® images 1A/1B showed similar optic disk diameters (ODD) (ODDA/ODDB = 1.00). Image 1A and 1B were further compared by calculating the index-ratio between the distance from the optic disk in image 1A and 1B (ODA and ODB) to the point of venous branching (PVB A1–A6, B1–B6), respectively, in image 1A/1B and by calculating the index-ratio between the PVB (A1–A6, B1–B6) in image 1A/1B. This revealed a highly inconsistent distortion pattern with indexing varying from 1.00 (no difference) to 0.74 (upto 26% difference in|A4A5→|/|B4B5→|). The index-ratio is presented in Table 1. These Optos® Images (1A and 1B) highlight there is no simple correction factor, as the distortion is inconsistent within the image. This warrants a need for further evaluation and a better understanding of the algorithm in the ultra-widefield imaging system converting the 3-D globe as a 2D image. Finally, we recommend that Optos® ultra-wide imaging is not used as the only imaging modality in evaluation and follow-up of intraocular tumours.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.615
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.043
GPT teacher head0.309
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueActa OphthalmologicaSame topicRetinal Diseases and TreatmentsFrench-language works237,207