MétaCan
Menu
← Back to cohort
Record W2897342818 · doi:10.1109/biorob.2018.8487932

Initial Investigation of a Self-Adjusting Wrist Control System to Maintain Prosthesis Terminal Device Orientation Relative to the Ground Reference Frame

2018· article· en· W2897342818 on OpenAlexafffund
Dylan J. A. Brenneis, Michael R. Dawson, Glyn S. Murgatroyd, Jason P. Carey, Patrick M. Pilarski

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsGlenrose Rehabilitation HospitalAlberta Health ServicesUniversity of Alberta
FundersCanada Research ChairsGlenrose Rehabilitation HospitalGovernment of Alberta
KeywordsWristDeskComputer scienceTask (project management)Orientation (vector space)Frame (networking)ForearmControl (management)SimulationPhysical medicine and rehabilitationHuman–computer interactionComputer visionArtificial intelligenceEngineeringMedicineMathematicsSurgery

Abstract

fetched live from OpenAlex

Lack of adequate wrist control in prostheses forces people with upper limb amputations to use compensatory movements that eventually result in overuse injuries. This is partly because conventional control of myoelectric wrists involves switching between directly controlling the wrist and fixing the wrist relative to the forearm. We propose that by implementing a wrist that is able to maintain the hand's orientation relative to the ground reference frame, here termed a self-adjusting wrist, users may see benefits in terms of both compensatory movements and ease of control. In this design study, we describe a simple initial implementation of a self-adjusting wrist. We then introduce and compare five control methods for the system. These methods were tested with six able-bodied participants who used a desk-mounted robotic arm to perform an object transfer and manipulation task. Quantitative and qualitative analyses coupled with user feedback suggest that a self-adjusting wrist may reduce task completion time and number of control interactions, and increase user satisfaction compared to conventional switching-based control. Our results indicate that use of a momentary switch to toggle a robotic hand's orientation between being fixed to the ground reference frame and being either fixed to the forearm reference frame or employing direct wrist control may be the best choice for a self-adjusting wrist. More broadly, by considering a wrist that automatically and continually orients itself to the user and their environment, this work contributes insight about how prostheses and other assistive robotic technology may intelligently adapt in real time to support the daily-life tasks faced by their users.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.249
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2018
Admission routes2
Has abstractyes

Explore more

Same topicMuscle activation and electromyography studies→French-language works237,207→