MétaCan
Menu
Back to cohort
Record W2899510108 · doi:10.1002/mrm.27479

Optimization of steady‐state free precession MRI for lung ventilation imaging with <sup>19</sup>F C<sub>3</sub>F<sub>8</sub> at 1.5T and 3T

2018· article· en· W2899510108 on OpenAlexfundno aff
Adam Maunder, Madhwesha Rao, Fraser Robb, Jim M. Wild

Bibliographic record

VenueMagnetic Resonance in Medicine · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of CanadaBritish Heart FoundationMedical Research CouncilNational Institute for Health and Care Research
KeywordsSteady-state free precession imagingIn vivoImaging phantomNuclear magnetic resonanceNuclear medicineMagnetic resonance imagingGradient echoVentilation (architecture)Steady state (chemistry)Relaxation (psychology)Biomedical engineeringMaterials sciencePhysicsChemistryMedicineRadiologyBiologyInternal medicine

Abstract

fetched live from OpenAlex

Purpose: To optimize 19 F imaging pulse sequences for perfluoropropane (C 3 F 8 ) gas human lung ventilation MRI considering intrinsic in vivo relaxation parameters at both 1.5T and 3T. Methods: Optimization of the imaging parameters for both 3D spoiled gradient (SPGR) and steady‐state free precession (SSFP) 19 F imaging sequences with inhaled 79% C 3 F 8% and 21% oxygen was performed. Phantom measurements were used to validate simulations of SNR. In vivo parameter mapping and sequence optimization and comparison was performed by imaging the lungs of a healthy adult volunteer. T 1 and T 2 * mapping was performed in vivo to optimize sequence parameters for in vivo lung MRI. The performance of SSFP and SPGR was then evaluated in vivo at 1.5T and 3T. Results: The in vivo T 2 * of C 3 F 8 was shown to be dependent upon lung inflation level (2.04 ms ± 36% for residual volume and 3.14 ms ± 28% for total lung capacity measured at 3T), with lower T 2 * observed near the susceptibility interfaces of the diaphragm and around pulmonary blood vessels. Simulation and phantom measurements indicate that a factor of ~2‐3 higher SNR can be achieved with SSFP when compared with optimized SPGR. In vivo lung imaging showed a 1.7 factor of improvement in SNR achieved at 1.5T, while the theoretical improvement at 3T was not attained due to experimental SAR constraints, shorter in vivo T 1 , and B 0 inhomogeneity. Conclusion: SSFP imaging provides increased SNR in lung ventilation imaging of C 3 F 8 demonstrated at 1.5T with optimized SSFP similar to the SNR that can be obtained at 3T with optimized SPGR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.911
Threshold uncertainty score0.863

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.271
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207