Effect of Simulated Pulpal Microcirculation on Temperature When Light Curing Bulk Fill Composites
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
SUMMARY Objectives: To evaluate the effect of light curing bulk fill resin composite restorations on the increase in the temperature of the pulp chamber both with and without a simulated pulpal fluid flow. Methods and Materials: Forty extracted human molars received a flat occlusal cavity, leaving approximately 2 mm of dentin over the pulp. The teeth were restored using a self-etch adhesive system (Clearfil SE Bond, Kuraray) and two different bulk fill resin composites: a flowable (SDR, Dentsply) and a regular paste (AURA, SDI) bulk fill. The adhesive was light cured for 20 seconds, SDR was light cured for 20 seconds, and AURA was light cured for 40 seconds using the Bluephase G2 (Ivoclar Vivadent) or the VALO Cordless (Ultradent) in the standard output power mode. The degree of conversion (DC) at the top and bottom of the bulk fill resin composite was assessed using Fourier-Transform Infra Red spectroscopy. The temperature in the pulp chamber when light curing the adhesive system and resin composite was measured using a J-type thermocouple both with and without the presence of a simulated microcirculation of 1.0-1.4 mL/min. Data were analyzed using Student t-tests and two-way and three-way analyses of variance (α=0.05 significance level). Results: The irradiance delivered by the light-curing units (LCUs) was greatest close to the top sensor of the MARC resin calibrator (BlueLight Analytics) and lowest after passing through the 4.0 mm of resin composite plus 2.0 mm of dentin. In general, the Bluephase G2 delivered a higher irradiance than did the VALO Cordless. The resin composite, LCU, and region all influenced the degree of cure. The simulated pulpal microcirculation significantly reduced the temperature increase. The greatest temperature rise occurred when the adhesive system was light cured. The Bluephase G2 produced a rise of 6°C, and the VALO Cordless produced a lower temperature change (4°C) when light curing the adhesive system for 20 seconds without pulpal microcirculation. Light curing SDR produced the greatest exothermic reaction. Conclusions: Using simulated pulpal microcirculation resulted in lower temperature increases. The flowable composite (SDR) allowed more light transmission and had a higher degree of conversion than did the regular paste (AURA). The greatest temperature rise occurred when light curing the adhesive system alone.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it