Disposable silicon-glass microfluidic devices: precise, robust and cheap
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Si-glass microfluidics have long provided unprecedented precision, robustness and optical clarity. However, chip fabrication is costly (∼500 USD per chip) and in practice, devices are not heavily reused. We present a method to reduce the cost-per-chip by two orders of magnitude (∼5 USD per chip), rendering Si-glass microfluidics disposable for many applications. The strategy is based on reducing the area of the chip and a whole-chip manifolding strategy that achieves reliable high-pressure high-temperature fluid connectivity. The resulting system was validated at 130 bar and 95 °C and demonstrated in both energy and carbon capture applications. We studied heavy oil flooding with brine, polymer, and surfactant polymer solutions and found the surfactant polymer as the most effective solution which recovered ∼80% of the oil with the least amount of injection while maintaining a relatively uniform displacement front. In a carbon capture application, we measured the dilation of an emerging ionic liquid analog, choline chloride with urea, in gaseous and supercritical CO2. Previously restricted to niche microfluidic applications, the approach here brings the established benefits of Si-glass microfluidics to a broad range of applications.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it