MétaCan
Menu
Back to cohort
Record W2901519773 · doi:10.1097/der.0000000000000417

North American Contact Dermatitis Group Patch Test Results: 2015–2016

2018· article· en· W2901519773 on OpenAlexaffvenue
Joel G. DeKoven, Erin M. Warshaw, Kathryn A. Zug, Howard I. Maibach, D. Belsito, Denis Sasseville, James S. Taylor, Joseph F. Fowler, C. G. Toby Mathias, James G. Marks, Melanie D. Pratt, Matthew Zirwas, Vincent A. DeLeo

Bibliographic record

VenueDermatitis · 2018
Typearticle
Languageen
FieldMedicine
TopicContact Dermatitis and Allergies
Canadian institutionsMcGill UniversityUniversity of OttawaRoyal Victoria HospitalUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicinePatch testAllergenContact dermatitisAllergic contact dermatitisConfidence intervalAmmonium persulfateDermatologyPatch testingInternal medicineAllergyImmunology

Abstract

fetched live from OpenAlex

BACKGROUND: Patch testing is an important diagnostic tool for the assessment of allergic contact dermatitis (ACD). OBJECTIVE: This study documents the North American Contact Dermatitis Group (NACDG) patch testing results from January 1, 2015, to February 28, 2017. METHODS: At 13 centers in North America, patients were tested in a standardized manner with a screening series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends were analyzed using χ test. RESULTS: A total of 5597 patients were tested. There were 3725 patients (66.6%) who had at least 1 positive reaction, and 2798 patients (50.2%) were ultimately determined to have a primary diagnosis of ACD. A total of 572 patients (10.2%) had occupationally related skin disease. There were 10,983 positive allergic reactions. Nickel remained the most commonly detected allergen (17.5%). Methylisothiazolinone, which was added to the screening series for the 2013-2014 cycle, had the second highest positive reaction rate of allergens tested (13.4%). Compared with the previous reporting periods (2013-2014) and (2005-2014), positive reaction rates for the top 35 screening allergens statistically increased for only 1 allergen: hydroxyethyl methacrylate (3.4%; risk ratios, 1.24 [confidence interval, 1.00-1.54] and 1.46 [confidence interval, 1.23-1.73]). Three newly added allergen preparations-ammonium persulfate (1.7%), chlorhexidine (0.8%), and hydroquinone (0.3%)-all had a reaction rate of less than 2%. Twenty-three percent of the tested patients had at least 1 relevant allergic reaction to an allergen not on the NACDG series; 12% of these were occupationally related. T.R.U.E. Test (SmartPractice Denmark, Hillerød, Denmark) would have hypothetically missed one quarter to almost 40% of reactions detected by the NACDG screening series. CONCLUSIONS: These results confirm that the epidemic of sensitivity to methylisothiazolinone has continued in North America. Patch testing with allergens beyond a screening tray is necessary for a complete evaluation of occupational and nonoccupational ACD.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0030.003
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0060.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.253
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations271
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueDermatitisSame topicContact Dermatitis and AllergiesFrench-language works237,207