MétaCan
Menu
Back to cohort
Record W2901687371 · doi:10.2196/11606

The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review

2018· review· en· W2901687371 on OpenAlexaffvenue
Ka Hou Christien Li, Francesca Anne White, Timothy Tipoe, Tong Liu, Martin C. S. Wong, Aaron Jesuthasan, Adrián Baranchuk, Gary Tse, Bryan P. Yan

Bibliographic record

VenueJMIR mhealth and uhealth · 2018
Typereview
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsKingston General HospitalQueen's University
Fundersnot available
KeywordsMobile phoneAtrial fibrillationChecklistMedicinePhoneMobile deviceNarrative reviewComputer scienceCardiologyIntensive care medicinePsychologyTelecommunicationsWorld Wide Web

Abstract

fetched live from OpenAlex

BACKGROUND: Mobile phone apps capable of monitoring arrhythmias and heart rate (HR) are increasingly used for screening, diagnosis, and monitoring of HR and rhythm disorders such as atrial fibrillation (AF). These apps involve either the use of (1) photoplethysmographic recording or (2) a handheld external electrocardiographic recording device attached to the mobile phone or wristband. OBJECTIVE: This review seeks to explore the current state of mobile phone apps in cardiac rhythmology while highlighting shortcomings for further research. METHODS: We conducted a narrative review of the use of mobile phone devices by searching PubMed and EMBASE from their inception to October 2018. Potentially relevant papers were then compared against a checklist for relevance and reviewed independently for inclusion, with focus on 4 allocated topics of (1) mobile phone monitoring, (2) AF, (3) HR, and (4) HR variability (HRV). RESULTS: The findings of this narrative review suggest that there is a role for mobile phone apps in the diagnosis, monitoring, and screening for arrhythmias and HR. Photoplethysmography and handheld electrocardiograph recorders are the 2 main techniques adopted in monitoring HR, HRV, and AF. CONCLUSIONS: A number of studies have demonstrated high accuracy of a number of different mobile devices for the detection of AF. However, further studies are warranted to validate their use for large scale AF screening.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.035
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.009
Threshold uncertainty score0.028

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.035
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0090.007
Science and technology studies0.0010.001
Scholarly communication0.0030.003
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.067
GPT teacher head0.402
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations165
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueJMIR mhealth and uhealthSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207