Distal Biceps Repair With Flexible Instrumentation and Risk of Posterior Interosseous Nerve Injury: A Cadaveric Analysis
Bibliographic record
Abstract
Background: Current repair techniques using cortical button fixation cannot achieve anatomic reconstruction of the distal biceps when performed through a single-incision anterior approach. We recently introduced a single-incision technique that uses flexible guide pins and flexible reamers to allow for an insertion point on the tuberosity that more closely approximates the anatomic footprint of the distal biceps. Purpose: To investigate the safety of this technique with regard to nerve injury by comparing the guide pin position relative to the posterior interosseous nerve in 16 cadaveric elbows through use of a flexible versus rigid reamer. Study Design: Descriptive laboratory study. Methods: A standard single-incision anterior approach was performed in all cadaveric specimens, and the biceps tendon was dissected off the tuberosity. In 8 specimens, a traditional straight guide pin was used with a cortical button repair inserted through the bicipital tuberosity as close to the anatomic tendon footprint as possible. In the remaining 8 specimens, a curved guide was used to insert a flexible guide wire through the tuberosity within the native footprint. Dissection was carried out to measure the distance from the exit point of the guide pin to the posterior interosseous nerve. The 2 groups were compared by use of nonparametric Wilcoxon rank-sum test (significance threshold, P < .05). Results: The mean distance of the guide wire to the posterior interosseous nerve was 11.6 mm (SD, 3.4 mm; range, 6.5-16.9 mm) in the standard rigid instrument group compared with 8.6 mm (SD, 4.2 mm; range, 1.0-13.9 mm) in the flexible instrumentation group; the difference between groups was not statistically different ( P = .19; 95% CI, –1.1 to 7.1). Conclusion: Based on our cadaveric testing, the use of flexible instrumentation in a single-incision repair of the distal biceps presents with no significant difference in risk of damage to the posterior interosseous nerve compared with standard rigid instruments. In view of the relatively small number of specimens, however, some caution should be observed when applying these results clinically. Clinical Relevance: As contemporary techniques in sports medicine strive to re-create each patient’s native anatomic characteristics, the use of flexible instruments allows for a more anatomic repair of the distal biceps, and our study demonstrates that it is a safe option. The next step is to evaluate its safety in vivo.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".