MétaCan
Menu
Back to cohort

Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head

2018· article· en· W2903511202 on OpenAlexaff
Lucas A. Torres, Faisal Jarrar, Glen P. Sharpe, Donna M. Hutchison, Eduardo Ferracioli-Oda, Marcelo Hatanaka, Marcelo T. Nicolela, Jayme R Vianna, Balwantray C. Chauhan

Bibliographic record

VenueBritish Journal of Ophthalmology · 2018
Typearticle
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMedicineRetinalOptic nerveGlaucomaOphthalmologyOptical coherence tomographyVisual fieldNerve fibre layerReceiver operating characteristicNerve fiber layerOptic diskLimits of agreementNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND/AIMS: Optical coherence tomography (OCT) imaging of the optic nerve head minimum rim width (MRW) has recently been shown to sometimes contain components besides extended retinal nerve fibre layer (RNFL). This study was conducted to determine whether excluding these components, termed protruded retinal layers (PRLs), from MRW increases diagnostic accuracy for detecting glaucoma. METHODS: In this cross-sectional study, we included 123 patients with glaucoma and 123 normal age-similar controls with OCT imaging of the optic nerve head (24 radial scans) and RNFL (circle scan). When present, PRLs were manually segmented, and adjusted MRW measurements were computed. We compared diagnostic accuracy of adjusted versus unadjusted MRW measurement. We also determined whether adjusted MRW correlates better with RNFL thickness compared with unadjusted MRW. RESULTS: The median (IQR) visual field mean deviation of patients and controls was -4.4 (-10.3 to -2.1) dB and 0.0 (-0.6 to 0.8) dB, respectively. In the 5904 individual B-scans, PRLs were identified less frequently in patients (448, 7.6%) compared with controls (728, 12.3%; p<0.01) and were present most frequently in the temporal sector of both groups. Areas under the receiver operating characteristic curves and sensitivity values at 95% specificity indicated that PRL adjustment did not improve diagnostic accuracy of MRW, globally or temporally. Furthermore, adjusting MRW for PRL did not improve its correlation with RNFL thickness in either group. CONCLUSION: While layers besides the RNFL are sometimes included in OCT measurements of MRW, subtracting these layers does not impact clinical utility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.114
Threshold uncertainty score0.375

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.344
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of OphthalmologySame topicGlaucoma and retinal disordersFrench-language works237,207