MétaCan
Menu
Back to cohort
Record W2904553828 · doi:10.1016/j.knee.2018.11.002

Repeatability of measuring knee flexion angles with wearable inertial sensors

2018· article· en· W2904553828 on OpenAlexafffund
Megan Christine Fennema, Riley A. Bloomfield, Brent A. Lanting, Trevor B. Birmingham, Matthew G. Teeter

Bibliographic record

VenueThe Knee · 2018
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsFowler Kennedy Sport Medicine ClinicLondon Health Sciences CentreLawson Health Research InstituteWestern University
FundersCanadian Institutes of Health ResearchWestern UniversityArthritis Society
KeywordsRepeatabilityGoniometerInertial measurement unitImaging phantomStandard deviationAccuracy and precisionComputer scienceBiomedical engineeringComputer visionMathematicsPhysicsEngineeringOptics

Abstract

fetched live from OpenAlex

BACKGROUND: As assessment with inertial-measurement-units (IMUs) increases in research and in clinics, it is important to be aware of the repeatability of these sensors. The objectives of this experiment were to evaluate the measurement repeatability of IMU joint angles using a repeatable robot controller and an anthropomorphic leg phantom and to determine effects of joint speed and sensor positioning on the angles collected by these sensors. Comparisons to an electro-goniometer and three-dimensional (3D) motion capture cameras were also completed. METHODS: Two dual-IMU setups (posterior and lateral) were tested concurrently with an electro-goniometer and 3D motion capture cameras using a repeatable robot controller and a leg phantom. All modalities were attached to the phantom, which was flexed 10 times using a pre-programmed motion pathway during each test. Mean angles were compared across tests. Effects of joint speed, sensor re-positioning, and anatomical placement of the sensors on repeatability were assessed. RESULTS: Re-positioning caused greater deviation to the maximum and minimum angles than differences in speed. Overall, the means ± standard deviations, and 95% confidence intervals of the maximum angles across all tests for the 3D camera markers, electro-goniometer, posterior IMUs, and lateral IMUs were 119.4 ± 0.3° (119.4, 119.5), 112.4 ± 0.5° (112.3, 112.5), 116.2 ± 2.4° (115.7, 116.7), and 118.3 ± 1.1° (118.1, 118.6). CONCLUSIONS: Both posterior and lateral IMU setups demonstrated acceptable repeatability in measurement of range of motion that was advantageous to manual goniometer methods. Posterior and lateral IMU setups demonstrated overlapping standard deviations about their means.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.017
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.250
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueThe KneeSame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207