MétaCan
Menu
Back to cohort
Record W2905154773 · doi:10.1063/1.5054749

Apparatus and method for efficient sampling of critical parameters demonstrated by monitoring an Overhauser geomagnetic sensor

2018· article· en· W2905154773 on OpenAlexaff
Huan Liu, Haobin Dong, Jian Ge, Zheng Liu, Zhiwen Yuan, Jun Zhu, Haiyang Zhang

Bibliographic record

VenueReview of Scientific Instruments · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicNMR spectroscopy and applications
Canadian institutionsOkanagan University CollegeUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersNational Natural Science Foundation of China
KeywordsEarth's magnetic fieldSampling (signal processing)Nuclear magnetic resonanceMaterials sciencePhysicsOpticsMagnetic fieldDetector

Abstract

fetched live from OpenAlex

The polarization frequency of free radical solution in Overhauser geomagnetic sensor determines the quality of the Larmor precession signal generated by the sensor. To obtain the polarization frequency accurately, a test apparatus was designed in this paper, which can overcome existing problems in the presently used apparatuses, such as lower resolution, complex operation, etc. The proposed apparatus adopts a high-resolution direct digital synthesis as the controllable radio frequency (RF) signal source. Meanwhile, an analog-to-digital converter synchronization acquisition technology combined with a normalization approach is proposed, which effectively solves the problem of the uneven amplitude-frequency characteristic in the range of 50 MHz-100 MHz. Moreover, the apparatus is integrated by adopting the RF power and applying the weak signal amplifier as an auxiliary measurement channel. The equivalent circuit of the sensors resonant cavity was simulated, and the efficiency curve of the adjustable capacitors to the resonant frequency and the quality factor were obtained. The simulated results were further verified by testing the resonance cavity characteristics of a commercial Overhauser geomagnetic sensor under different conditions. Furthermore, the relationship between the polarization degree of the free radical solution and RF excitation power and time were also obtained. The testing methods and results were given, and the experimental data were analyzed. Finally, the experimental results demonstrate that the proposed apparatus can measure the polarization frequency of the free radical solution, the bandwidth, and the quality factor, accurately. Furthermore, it can be used for the determination of the polarization power and time during the design process for an Overhauser magnetometer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.254
Threshold uncertainty score0.433

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.404
Teacher spread0.371 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicNMR spectroscopy and applicationsFrench-language works237,207