Development, Evaluation, and Implementation of a New 3D Printed Tongue Depressor Dispenser
Bibliographic record
Abstract
The purpose of this technical report was two-fold. First was to describe the concept, development and initial implementation of a three-dimensional (3D) printing network focussed on manufacturing simulators and simple devices necessary to the functioning of rural hospital and clinics. Second was to describe the design, fabrication and user-based evaluation of a cost-effective tongue depressor dispenser. The initial successful setup and implementation of the 3D printing network were modelled using four of the five implementation constructs derived from the Consolidated Framework for Implementation Research (CFIR). The 3D printing of the tongue depressor dispenser was found to be an effective and economic initiative. Without considering the initial design costs, the materials costs were estimated at $6 Canadian per dispenser. After installation of the dispenser in a busy emergency department, hospital leadership and staff viewed it as a safer option to the current dispense, and more affordable.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.017 | 0.016 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.003 | 0.002 |
| Open science | 0.003 | 0.002 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.004 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".