MétaCan
Menu
Back to cohort
Record W2907927303 · doi:10.1089/thy.2018.0439

A Practical Approach for the Verification and Determination of Site- and Trimester-Specific Reference Intervals for Thyroid Function Tests in Pregnancy

2018· article· en· W2907927303 on OpenAlex
Lois Donovan, Amy Metcalfe, Alex Chin, Jennifer M. Yamamoto, Heidi Virtanen, Jo-Ann Johnson, Richard Krause

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueThyroid · 2018
Typearticle
Languageen
FieldMedicine
TopicThyroid Disorders and Treatments
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsMedicineThyroid functionThyroid peroxidasePregnancyThyroid function testsPopulationObstetricsThyroid diseaseGynecologyThyroid-stimulating hormoneThyroidInternal medicineBiology

Abstract

fetched live from OpenAlex

BACKGROUND: Population-, assay-, and trimester-specific reference intervals for thyroid function tests are necessary to assess thyroid status accurately and manage thyroid disease throughout pregnancy. This study's objective was to verify if the manufacturer's recommended trimester-specific reference intervals for thyroid tests and the American Thyroid Association's recommended total thyroxine (TT4) pregnancy reference intervals were verifiable and appropriate for use in the authors' multicultural population. METHODS: Blood samples were obtained from the following sources: stored frozen surplus blood from women undergoing routine aneuploidy screening (first- and second-trimester samples, n = 274), women participating in an observational cohort study (second- and third-trimester samples, n = 135), and blood collected from women presenting for assessment to the labor and delivery ward (third-trimester samples, n = 35). Exclusions included thyroid medication or disease and positive thyroid peroxidase antibodies (anti-TPO). Samples were analyzed for thyrotropin (TSH), free T4 (fT4), free triiodothyronine (fT3), TT4, and anti-TPO using the Roche Cobas 8000 Modular e602 electrochemiluminescence immunoassay. RESULTS: Nine percent of the aneuploidy screening samples were excluded prior to thyroid testing due to maternal use of thyroid medication. Six percent of analyzed samples were excluded: 5.9% with positive anti-TPO and one with a TSH >10 mIU/L. The manufacturer's recommended trimester-specific reference intervals for TSH were not verified by described standardized methods. Therefore, 95th percentile reference intervals were determined using a minimum number of samples. Reference intervals for TSH and fT4 were as follows: 9-12 weeks, 0.18-2.99 mIU/L and 11-19.2 pmol/L; second trimester, 0.11-3.98 mIU/L and 10.5-18.2 pmol/L; and third trimester, 0.48-4.71 mIU/L and 9.0-16.1 pmol/L, respectively. The TT4 reference interval after 19 weeks' gestation was 77-186 nmol/L. CONCLUSIONS: This study provides a simple approach to verify or establish trimester-specific thyroid function reference intervals in local populations. The TT4 reference interval was lower than the interval proposed by the American Thyroid Association, suggesting the need for further study of TT4 in pregnancy and reliance on locally established fT4 reference intervals after 19 weeks, especially when there are no equivalent reference intervals for TT4.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.828
Threshold uncertainty score0.305

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.069
GPT teacher head0.339
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it