MétaCan
Menu
Back to cohort
Record W2907959725 · doi:10.1002/cmr.a.21465

Optimization of a parallel‐plate <scp>RF</scp> probe for high resolution thin film imaging

2018· article· en· W2907959725 on OpenAlex
Andrés Ramírez Aguilera, Bryce MacMillan, Gillian R. Goward, Bruce J. Balcom

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueConcepts in Magnetic Resonance Part A · 2018
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsMcMaster UniversityUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsHomogeneity (statistics)ResonatorMagnetic fieldMaterials sciencePerpendicularElectromagnetic coilOpticsNuclear magnetic resonanceOptoelectronicsElectrical engineeringPhysicsComputer science

Abstract

fetched live from OpenAlex

Abstract Choosing an MR probe with the correct dimensions and high sensitivity is critical for magnetic resonance imaging, especially high resolution thin film imaging. In this work, a parallel‐plate resonator has been optimized for strength and uniformity of the B 1 magnetic field. The parallel‐plate resonator is designed for high resolution imaging in the direction perpendicular to the plates. The optimization process was undertaken through simulation with CST Micro Wave Studio, followed by experiment. A 400 μm capillary tube, filled with doped water, was used for testing the optimized probe in a 2.4 T magnet. It is shown that increasing the width of the copper leads connected to the plates increases the homogeneity of the B 1 magnetic field by almost 90%. The best approach to increase the sensitivity and the homogeneity of the probe was to maintain the dimensions of the plates and copper leads but to add additional capacitors at the corners to distribute the current. This approach produces a 40% stronger B 1 magnetic field and increases the homogeneity by almost 85%. The experimental B 1 magnetic field of the parallel‐plate prototype agrees within 20% of the value found through simulation, for specified power. The experimental MRI results show that it is possible to achieve a nominal resolution of 10 μm between the plates for suitable samples using the optimized probe. The optimized parallel‐plate resonator, combined with a phase encode SE SPI method, may be used for high resolution studies of lithium‐ion transport in the electrolyte solution of lithium‐ion batteries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.394
Threshold uncertainty score0.606

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.313
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it