MétaCan
Menu
Back to cohort
Record W2907959725 · doi:10.1002/cmr.a.21465

Optimization of a parallel‐plate <scp>RF</scp> probe for high resolution thin film imaging

2018· article· en· W2907959725 on OpenAlexafffund
Andrés Ramírez Aguilera, Bryce MacMillan, Gillian R. Goward, Bruce J. Balcom

Bibliographic record

VenueConcepts in Magnetic Resonance Part A · 2018
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsMcMaster UniversityUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsHomogeneity (statistics)ResonatorMagnetic fieldMaterials sciencePerpendicularElectromagnetic coilOpticsNuclear magnetic resonanceOptoelectronicsElectrical engineeringPhysicsComputer science

Abstract

fetched live from OpenAlex

Abstract Choosing an MR probe with the correct dimensions and high sensitivity is critical for magnetic resonance imaging, especially high resolution thin film imaging. In this work, a parallel‐plate resonator has been optimized for strength and uniformity of the B1 magnetic field. The parallel‐plate resonator is designed for high resolution imaging in the direction perpendicular to the plates. The optimization process was undertaken through simulation with CST Micro Wave Studio, followed by experiment. A 400 μm capillary tube, filled with doped water, was used for testing the optimized probe in a 2.4 T magnet. It is shown that increasing the width of the copper leads connected to the plates increases the homogeneity of the B1 magnetic field by almost 90%. The best approach to increase the sensitivity and the homogeneity of the probe was to maintain the dimensions of the plates and copper leads but to add additional capacitors at the corners to distribute the current. This approach produces a 40% stronger B1 magnetic field and increases the homogeneity by almost 85%. The experimental B1 magnetic field of the parallel‐plate prototype agrees within 20% of the value found through simulation, for specified power. The experimental MRI results show that it is possible to achieve a nominal resolution of 10 μm between the plates for suitable samples using the optimized probe. The optimized parallel‐plate resonator, combined with a phase encode SE SPI method, may be used for high resolution studies of lithium‐ion transport in the electrolyte solution of lithium‐ion batteries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.313
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueConcepts in Magnetic Resonance Part ASame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207