MétaCan
Menu
Back to cohort
Record W2908173197 · doi:10.1002/mp.13375

An investigation of the effect of fat suppression and dimensionality on the accuracy of breast MRI segmentation using U‐nets

2019· article· en· W2908173197 on OpenAlexafffund
Homa Fashandi, Yingli Lu, WU Hong-bo, Anne L. Martel

Bibliographic record

VenueMedical Physics · 2019
Typearticle
Languageen
FieldComputer Science
TopicAI in cancer detection
Canadian institutionsUniversity of TorontoSunnybrook HospitalSunnybrook Health Science Centre
FundersFedDev OntarioSunnybrook Research Institute
KeywordsGround truthSegmentationCurse of dimensionalityArtificial intelligenceBreast MRIBreast cancerComputer sciencePattern recognition (psychology)Digital mammographyHyperparameterImage qualityData setBreast imagingMammographyMedicineImage (mathematics)CancerInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: Accurate segmentation of the breast is required for breast density estimation and the assessment of background parenchymal enhancement, both of which have been shown to be related to breast cancer risk. The MRI breast segmentation task is challenging, and recent work has demonstrated that convolutional neural networks perform well for this task. In this study, we have investigated the performance of several two-dimensional (2D) U-Net and three-dimensional (3D) U-Net configurations using both fat-suppressed and nonfat-suppressed images. We have also assessed the effect of changing the number and quality of the ground truth segmentations. MATERIALS AND METHODS: We designed eight studies to investigate the effect of input types and the dimensionality of the U-Net operations for the breast MRI segmentation. Our training data contained 70 whole breast volumes of T1-weighted sequences without fat suppression (WOFS) and with fat suppression (FS). For each subject, we registered the WOFS and FS volumes together before manually segmenting the breast to generate ground truth. We compared four different input types to the U-nets: WOFS, FS, MIXED (WOFS and FS images treated as separate samples), and MULTI (WOFS and FS images combined into a single multichannel image). We trained 2D U-Nets and 3D U-Nets with these data, which resulted in our eight studies (2D-WOFS, 3D-WOFS, 2D-FS, 3D-FS, 2D-MIXED, 3D-MIXED, 2D-MULTI, and 3D-MULT). For each of these studies, we performed a systematic grid search to tune the hyperparameters of the U-Nets. A separate validation set with 15 whole breast volumes was used for hyperparameter tuning. We performed Kruskal-Walis test on the results of our hyperparameter tuning and did not find a statistically significant difference in the ten top models of each study. For this reason, we chose the best model as the model with the highest mean dice similarity coefficient (DSC) value on the validation set. The reported test results are the results of the top model of each study on our test set which contained 19 whole breast volumes annotated by three readers fused with the STAPLE algorithm. We also investigated the effect of the quality of the training annotations and the number of training samples for this task. RESULTS: The study with the highest average DSC result was 3D-MULTI with 0.96 ± 0.02. The second highest average is 2D WOFS (0.96 ± 0.03), and the third is 2D MULTI (0.96 ± 0.03). We performed the Kruskal-Wallis one-way ANOVA test with Dunn's multiple comparison tests using Bonferroni P-value correction on the results of the selected model of each study and found that 3D-MULTI, 2D-MULTI, 3D-WOFS, 2D-WOFS, 2D-FS, and 3D-FS were not statistically different in their distributions, which indicates that comparable results could be obtained in fat-suppressed and nonfat-suppressed volumes and that there is no significant difference between the 3D and 2D approach. Our results also suggested that the networks trained on single sequence images or multiple sequence images organized in multichannel images perform better than the models trained on a mixture of volumes from different sequences. Our investigation of the size of the training set revealed that training a U-Net in this domain only requires a modest amount of training data and results obtained with 49 and 70 training datasets were not significantly different. CONCLUSIONS: To summarize, we investigated the use of 2D U-Nets and 3D U-Nets for breast volume segmentation in T1 fat-suppressed and without fat-suppressed volumes. Although our highest score was obtained in the 3D MULTI study, when we took advantage of information in both fat-suppressed and nonfat-suppressed volumes and their 3D structure, all of the methods we explored gave accurate segmentations with an average DSC on >94% demonstrating that the U-Net is a robust segmentation method for breast MRI volumes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.105
Threshold uncertainty score0.128

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.283
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAI in cancer detectionFrench-language works237,207