Cost-Effectiveness of the Aerobika® Oscillating Positive Expiratory Pressure Device in the Management of Chronic Obstructive Pulmonary Disease Exacerbations in Canada
Bibliographic record
Abstract
Background: The Aerobika® oscillating positive expiratory pressure (OPEP) device is a hand-held, drug-free medical device that has been shown to improve lung function and improve health-related quality of life in patients with chronic obstructive pulmonary disease (COPD). We estimated the cost-effectiveness of this device among postexacerbation COPD patients in the Canadian healthcare system. Methods: We performed a cost-utility analysis using a Markov model to compare both costs and outcome of patients with COPD who had recently experienced an exacerbation between 2 treatment arms: patients who used the Aerobika® device and patients who did not use the Aerobika® device. This cost-utility analysis included costs based on the Alberta healthcare system perspective as these represent Canadian experience. A one-year horizon with 12 monthly cycles was used. Results: For a patient after 1 year, the use of the Aerobika® device would save $694 in healthcare costs and produce 0.04 more in quality-adjusted life years (QALYs) in comparison with no positive expiratory pressure (PEP)/OPEP therapy. In other words, the economic outcome of the device was dominant (i.e., more effective and less costly). The probability for this device to be the dominant strategy was 72%. With a willingness to pay (WTP) threshold of $50,000 per QALY gained, the probability for the Aerobika® device to be cost-effective was 77%. Conclusions: Given one of the major treatment goals in the GOLD guidelines is to minimize the negative impact of exacerbations and prevent re-exacerbations, the Aerobika® OPEP device should be viewed as a potential component of a treatment strategy to improve symptom control and reduce the risk of re-exacerbations in patients with COPD.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.009 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.001 | 0.002 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.002 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".