MétaCan
Menu
Back to cohort
Record W2910929919 · doi:10.5114/jcb.2018.79928

Cost in perspective: direct assessment of American market acceptability of Co-60 in gynecologic high-dose-rate brachytherapy and contrast with experience abroad

2018· article· en· W2910929919 on OpenAlexfundno aff
Raymond B. Mailhot Vega, David Barbee, Wesley J. Talcott, T. Duckworth, B.A. Shah, O. Ishaq, Christina Small, Anamaria R. Yeung, Carmen A. Perez, Peter B. Schiff, Ophira Ginsburg, William Small, May Abdel–Wahab, Gustavo Sarria Bardales, Matthew M. Harkenrider

Bibliographic record

VenueJournal of Contemporary Brachytherapy · 2018
Typearticle
Languageen
FieldMedicine
TopicEndometrial and Cervical Cancer Treatments
Canadian institutionsnot available
FundersYork University
KeywordsMedicineBrachytherapyRespondentElectromagnetic shieldingMedical physicsWillingness to payReimbursementActivity-based costingFamily medicineRadiation therapyMarketingSurgeryHealth careBusinessEconomicsEconomic growth

Abstract

fetched live from OpenAlex

PURPOSE: While Ir-192 remains the mainstay isotope for gynecologic high-dose-rate (HDR) brachytherapy in the U.S., Co-60 is used abroad. Co-60 has a longer half-life than Ir-192, which may lead to long-term cost savings; however, its higher energy requires greater shielding. This study analyzes Co-60 acceptability based on a one-time expense of additional shielding and reports the financial experience of Co-60 in Peru's National Cancer Institute, which uses both isotopes. MATERIAL AND METHODS: A nationwide survey was undertaken assessing physician knowledge of Co-60 and willingness-to-pay (WTP) for additional shielding, assuming a source more cost-effective than Ir-192 was available. With 440 respondents, 280 clinicians were decision-makers and provided WTPs, with results previously reported. After completing a shielding report, we estimated costs for shielding expansion, noting acceptability to decision makers' WTP. Using activity-based costing, we note the Peruvian fiscal experience. RESULTS: Shielding estimates ranged from $173,000 to $418,000. The percentage of respondents accepting high-density modular or lead shielding (for union and non-union settings) were 17.5%, 11.4%, 3.9%, and 3.2%, respectively. Shielding acceptance was associated with greater number of radiation oncologists in a respondent's department but not time in practice or the American Brachytherapy Society membership. Peru's experience noted cost savings with Co-60 of $52,400 annually. CONCLUSIONS: By comparing the cost of additional shielding for a sample institution's HDR suite with radiation oncologists' WTP, this multi-institutional collaboration noted < 20% of clinicians would accept additional shielding. Despite low acceptability in the US, Co-60 demonstrates cost-favorability in Peru and may similarly in other locations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.011
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0060.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.381
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contemporary BrachytherapySame topicEndometrial and Cervical Cancer TreatmentsFrench-language works237,207