MétaCan
Menu
← Back to cohort
Record W2911047040 · doi:10.1002/mp.13384

Technical Note: Evaluation of kV CBCT enhancement using a liver‐specific contrast agent for stereotactic body radiation therapy image guidance

2019· article· en· W2911047040 on OpenAlexaff
John Lincoln, David Parsons, Sharon E. Clarke, Slawa Cwajna, James L. Robar

Bibliographic record

VenueMedical Physics · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsCone beam computed tomographyImaging phantomContrast-to-noise ratioNuclear medicineImage qualityMedicineMedical imagingImage-guided radiation therapyBiomedical engineeringComputed tomographyMaterials scienceRadiologyComputer scienceImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: USA, Bayer Healthcare, Leverkusen, Germany), a contrast agent that is taken up selectively by liver cells and is retained for up to an hour. Image quality from CBCT was benchmarked against helical fan-beam computed tomography for two phantom geometries. METHODS AND MATERIALS: Concentrations were diluted to 0.0125-0.1 mmol per kilogram of body weight (mmol/kg) corresponding to expected physiological concentrations in the liver. Kilovoltage CBCT imaging parameters of x-ray tube potential, current, and filtration were investigated using clinically available options on a TrueBeam STx linear accelerator CBCT platform. Two phantoms were created, a cylindrical idealized imaging geometry and an ellipsoidal more realistic abdominal geometry. All parameters were optimized according to the contrast-to-noise ratio (CNR) image quality metric, as a function of concentration, following the Rose criterion for CNR. RESULTS: Acceptable CNR was defined as greater than or equal to three, in accordance with the Rose criterion for CNR. These were found in a range of expected liver concentrations of 0.025-0.1 mmol/kg for a tube potential of 100 kVp, half-fan bowtie filtration and tube currents giving exposures between 2025 and 5085 mAs. Linear correlations were found for all CNR as a function of concentration, in agreement with the literature. CONCLUSION: Based on this phantom study, with appropriate selection of imaging protocol, Gadoxetate Disodium may provide useful liver CBCT enhancement at physiologically achievable liver concentrations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.347
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→