MétaCan
Menu
Back to cohort

Case Report: Argon Plasma Coagulation for the Treatment of Hemorrhagic Radiation Sigmoiditis

2007· article· en· W2911631607 on OpenAlexaffabout
Mindy Lam, Clarence Wong

Bibliographic record

VenueThe American Journal of Gastroenterology · 2007
Typearticle
Languageen
FieldMedicine
TopicEffects of Radiation Exposure
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsMedicineArgon plasma coagulationRadiation proctitisRadiation therapyAnemiaRadiation EnteritisColonoscopySurgeryBlood transfusionSigmoidoscopyColitisCancerColorectal cancerInternal medicineEndoscopyGastroenterologyUlcerative colitisProctitis

Abstract

fetched live from OpenAlex

Purpose: Radiation colitis is not an uncommon consequence of pelvic radiation, such as in patients treated for gynecologic cancers. Some of these patients may suffer from anemia requiring transfusion due to chronic bleeding. Many of these patients are managed with rectal medications, which is often inadequate for control. Argon plasma coagulation (APC) has been well described for its efficacy in treating radiation proctitis. Here, we present two cases in which APC therapy was used to treat radiation sigmoiditis. Methods: We followed two cases originally seen at our regional cancer centre (Cross Cancer Institute) in Edmonton, Alberta, Canada. Both patients received pelvic radiation for endometrial cancers and were referred for active bleeding secondary to radiation colitis that had required numerous transfusions. Results: Radiation induced telangiectasias were found from 10–50 cm in the sigmoid colon. Both patients had significant improvement of symptoms after one session of APC treatment set at 40–60 W and gas flow of 2.0 L/min. To assess the efficacy of treatment, a second endoscopy with APC was performed. There were no complications from the procedures. Neither patient require blood transfusions after the initial treatment with improvement in their hemoglobin levels and were doing well at four and ten-month follow up. Conclusion: Argon plasma coagulation can be used effectively to provide immediate and sustained resolution of symptoms in patients with radiation sigmoiditis (colitis).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.551
Threshold uncertainty score0.247

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.291
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueThe American Journal of GastroenterologySame topicEffects of Radiation ExposureFrench-language works237,207