MétaCan
Menu
Back to cohort
Record W2913386717 · doi:10.3171/2018.7.jns181164

Effective accuracy of stereoelectroencephalography: robotic 3D versus Talairach orthogonal approaches

2019· article· en· W2913386717 on OpenAlexaff
Pierre Bourdillon, Claude-Édouard Châtillon, Alexis Moles, Sylvain Rheims, Hélène Catenoix, Alexandra Montavont, Karine Ostrowsky‐Coste, Sébastien Boulogne, Jean Isnard, Marc Guénot

Bibliographic record

VenueJournal of neurosurgery · 2019
Typearticle
Languageen
FieldNeuroscience
TopicCerebrospinal fluid and hydrocephalus
Canadian institutionsUniversité de MontréalCentre intégré universitaire de santé et de services sociaux de la Mauricie-et-du-Centre-du-Québec
Fundersnot available
KeywordsStereoelectroencephalographyMedicineStereotaxyAngiographyNuclear medicineRadiologyEpilepsy surgeryArtificial intelligenceEpilepsyComputer science

Abstract

fetched live from OpenAlex

OBJECTIVE: Stereoelectroencephalography (SEEG) was first developed in the 1950s by Jean Talairach using 2D angiography and a frame-based, orthogonal approach through a metallic grid. Since then, various other frame-based and frameless techniques have been described. In this study the authors sought to compare the traditional orthogonal Talairach 2D angiographic approach with a frame-based 3D robotic procedure that included 3D angiographic interoperative imaging guidance. MRI was used for both procedures during surgery, but MRI preplanning was done only in the robotic 3D technique. METHODS: All study patients suffered from drug-resistant focal epilepsy and were treated at the same center by the same neurosurgical team. Fifty patients who underwent the 3D robotic procedure were compared to the same number of historical controls who had previously been successfully treated with the Talairach orthogonal procedure. The effectiveness and absolute accuracy, as well as safety, of the two procedures were compared. Moreover, in the 3D robotic group, the reliability of the preoperative MRI to avoid vascular structures was evaluated by studying the rate of trajectory modification following the coregistration of the intraoperative 3D angiographic data onto the preoperative MRI-based trajectory plans. RESULTS: Effective accuracy (96.5% vs 13.7%) and absolute accuracy (1.15 mm vs 4.00 mm) were significantly higher in the 3D robotic group than in the Talairach orthogonal group. Both procedures showed excellent safety results (no major complications). The rate of electrode modification after 3D angiography was 43.8%, and it was highest for frontal and insular locations. CONCLUSIONS: The frame-based, 3D angiographic, robotic procedure described here provided better accuracy for SEEG implantations than the traditional Talairach approach. This study also highlights the potential safety advantage of trajectory planning using intraoperative frame-based 3D angiography over preoperative MRI alone.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.265
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of neurosurgerySame topicCerebrospinal fluid and hydrocephalusFrench-language works237,207