Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy?
Bibliographic record
Abstract
PURPOSE: In this prospective phase II study, we investigated whether cone beam computed tomography scan was a superior method of image-guided radiotherapy relative to 2D orthogonal kilovoltage images in the post-radical prostatectomy setting. METHODS: A total of 419 treatment fractions were included in this analysis. The shifts required to align the patient for each treatment were performed using 3D matching between cone beam computed tomography scans and the corresponding computed tomography images used for planning. This was compared with the shifts obtained from 2D orthogonal kilovoltage images, matching with the corresponding digitally reconstructed radiographs. Patients did not have fiducials inserted to assist with localization. Interfractional changes in the bladder and rectal volumes were subsequently measured on the cone beam computed tomography images for each fraction and compared to the shift differences between orthogonal kilovoltage and cone beam computed tomography scans. The proportion of treatment fractions with a shift difference exceeding the planning target volume of 7 mm, between orthogonal kilovoltage and cone beam computed tomography scans, was calculated. RESULTS: The mean vertical, lateral, and longitudinal shifts resulted from 2D match between orthogonal kilovoltage images and corresponding digitally reconstructed radiographs were 0.353 cm (interquartile range: 0.1-0.5), 0.346 cm (interquartile range: 0.1-0.5), and 0.289 cm (interquartile range: 0.1-0.4), compared to 0.388 cm (interquartile range: 0.1-0.5), 0.342 cm (interquartile range: 0.1-0.5), and 0.291 cm (interquartile range: 0.1-0.4) obtained from 3D match between cone beam computed tomography and planning computed tomography scan, respectively. Our results show a significant difference between the kilovoltage and cone beam computed tomography shifts in the anterior-posterior direction ( P = .01). The proportion of treatment fractions in which the differences in kilovoltage and cone beam computed tomography shifts between exceeded the 7 mm planning target volume margin was 6%, 2%, and 3% in the anterior-posterior, lateral, and superior-inferior directions, respectively. CONCLUSION: We prospectively demonstrated that the daily use of volumetric cone beam computed tomography for treatment localization in post-radical prostatectomy patients demonstrated an increased need for a shift in patient position. This suggests that in post-radical prostatectomy patients the daily cone beam computed tomography imaging improved localization of the prostate bed and may have prevented a limited number of geographic misses, compared to daily kilovoltage imaging that was not assisted with fiducials.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".